| 数据搜索系统,热门电子元器件搜索 |
|
STE12PS 数据表(PDF) 12 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STE12PS 数据表(HTML) 12 Page - STMicroelectronics |
|
12 / 44 page ![]() Obsolete Product(s) - Obsolete Product(s) Functional description STE12PS 12/44 3.2.3 Detection and classification FSM This FSM manages all operations related to the detection and classification procedures. For these two procedures, the following assumptions are made: 1. A channel is detected ONLY if: a) the channel has not yet been detected, and Channel Detection has been enabled, and b) the Backoff Detection timer and Subsequent Attempt timer are NOT running (after a corresponding fault detection or failed signature). 2. A channel is classified ONLY if: a) Channel Classification is enabled, and b) the previous related detection procedure has reported an Rgood/Ggood value (Auto and SemiAuto modes). Three general macro operations can be performed: ● STARTUP: the following operations are related to the startup procedure: – RESET: reset and initialize all digital aspects of the STE12PS, – WAIT_POWER_UP: wait 100ms for completion of the power-up procedure. During this period, the I2C bus is active - allowing the host to initialize registers while the detection procedure is waiting to start. – DETECTION START: all setting-up needed to start operations is performed in this state. The first battery voltage sample is latched in a dedicated register. ● DETECTION: the following operations are related to the detection procedure for the channel selected: – Low voltage detection command (4V) is issued via registers; detection timer is started to execute the command for a duration of ½Tdet ms. – Wait for 5ms to acquire a stable measurement. – Sampled sensing current values are acquired via A/D converter. – The samples previously acquired are averaged and the resulting value, reported into the Channels Monitor register, is compared against programmed min/max values. If the sensing current is higher than maximum allowed value, the detection procedure is considered as having FAILED: backoff timer is started (Alternative B) and an alarm flag raised according to the Channel Status registers. – If the sensing current results lower than the minimum allowed value the detection procedure is continued: the alarm flag is raised in the Channel Status registers. – The described operations are repeated for the High-Voltage detection command (8 V). – Signature Resistance is calculated: – If 2µsec < Gmeas < Glow or Ghigh < Gmeas, then backoff timer is started (Alternative B) and detection result failure is reported in the Channel Status registers. – Else, Glow < Gmeas < Ghigh and the result of a successful detection is reported in the Channel Status registers. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |