| 数据搜索系统,热门电子元器件搜索 |
|
STE12PS 数据表(PDF) 14 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STE12PS 数据表(HTML) 14 Page - STMicroelectronics |
|
14 / 44 page ![]() Obsolete Product(s) - Obsolete Product(s) Functional description STE12PS 14/44 3.3 Power ON After the classification phase the port will be powered. Once activated, the power-on sequencer manages the channel’s activation requests received through the signature detection circuitry. For the incoming channel, activation requests are stored in the power-on sequencer and then serviced, one at a time, only when the previously activated channel leaves the current limiting condition that normally occurs during power on due to the capacitive part of the load. (see also smart-power mode and special issues) A port is turned-on by ramping-up the voltage and increasing the current limit to its upper limit. After a programmable time (Tinrush), if the port has reached full voltage and is out of current limitation, it is marked as powered. The related port power bit and the power class bits are set according to the class in the logic interface bit stream. The active ports are continuously monitored in order to detect a fault condition such as Short Circuit, Disconnection or Excess Power (overload). 3.3.1 Under load (disconnection) Detection of a disconnection, if enabled (default condition), can be performed via a DC and/or AC method - default is DC ⊕ AC (logical OR): ● DC method If this method is selected via the logic interface and if the port current drops under 7.5mA for more than 10ms, then the STE12PS will detect a DC disconnection. If this condition persist for Tmpdo ( Table 12), then power is removed and the port is marked as free, enabling a new detection. ● AC method If this method is selected via the logic interface, the STE12PS probes the channels via coupling capacitors and detects when the AC load impedance, Zac, exceeds the maximum, 100k Ω limit for a time longer than 20ms. In this case, the PSE will detect an AC disconnection. If this condition persist for a time Tmpdo ( Table 12), power is removed and the port is marked as free, enabling a new detection. Disconnection modes are as following: Disabled, DC method only, AC method only, both AC and DC (combined in OR ⊕ logic or in AND ⊗ logic). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |