Back Button ADIS16228/PCBZ Datasheet HTML 7Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 8Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 9Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 10Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 11Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 12Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 13Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 14Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 15Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 28 page
background image
Data Sheet
ADIS16228
Rev. B | Page 11 of 28
DATA RECORDING AND SIGNAL PROCESSING
The ADIS16228 provides a complete sensing system for recording
and monitoring vibration data. Figure 13 provides a simplified
block diagram for the signal processing associated with spectral
record acquisition on all three axes (x, y, z). User registers
provide controls for data type (time or frequency), trigger mode
(manual or automatic), collection mode (real time or capture),
sample rates/filtering, windowing, FFT averaging, spectral alarms,
and I/O management.
RECORDING MODE
The recording mode selection establishes the data type (time or
frequency domain), trigger type (manual or automatic), and
data collection (captured or real time). The REC_CTRL1[1:0]
bits (See Table 9) provide four operating modes: manual FFT,
automatic FFT, manual time capture, and real time. After setting
REC_CTRL1, the manual FFT, automatic FFT, and manual time
capture modes require a start command to start acquiring a
spectral or time domain record. There are two start command
options in this mode: SPI and I/O. The SPI trigger involves setting
GLOB_CMD[11] = 1 (DIN = 0xBF08). The I/O trigger involves
using DIO_CTRL (see Table 66) to configure DIO1 or DIO2 as
an input trigger line.
Table 9. REC_CTRL1 (Base Address = 0x1A), Read/Write
Bits
Description (Default = 0x1100)
[15:14]
Not used (don’t care).
[13:12]
Window setting.
00 = rectangular, 01 = Hanning, 10 = flat top, 11 = N/A.
11
SR3, 1 = enabled for FFT, 0 = disable.
Sample rate = 20,480 ÷ 2AVG_CNT[15:12] (see Table 11).
10
SR2, 1 = enabled for FFT, 0 = disable.
Sample rate = 20,480 ÷ 2AVG_CNT[11:8] (see Table 11).
9
SR1, 1 = enabled for FFT, 0 = disable.
Sample rate = 20,480 ÷ 2AVG_CNT[7:4] (see Table 11).
8
SR0, 1 = enabled for FFT, 0 = disable.
Sample rate = 20,480 ÷ 2AVG_CNT[3:0] (see Table 11).
7
Power-down between each recording. 1 = enabled.
[6:4]
Not used (don’t care).
[3:2]
Storage method.
00 = none, 01 = alarm trigger, 10 = all, 11 = N/A.
[1:0]
Recording mode.
00 = manual FFT, 01 = automatic FFT,
10 = manual time capture, 11 = real-time sampling/data
access.
Manual FFT Mode
Set REC_CTRL1[1:0] = 00 to place the device in manual FFT
mode. Then use a start command to trigger the production of a
spectral record. When the device is acquiring a spectral record,
use the busy indicator (DIO1, per factory default) to drive an
interrupt service line on an external processor, which can start
data collection after the process completes. DIAG_STAT is the
only register that the SPI can read while the device is processing
a command. Reading this register returns a 0x00 while the device
is busy and 0x80 when the data is ready for external access. When
the spectral record is complete, the device waits for another start
command.
Automatic FFT Mode
Set REC_CTRL1[1:0] = 01 to place the device in automatic FFT
mode. Use the REC_PRD register (see Table 10) to program the
period between production of each spectral record. Then use a
start command to trigger periodic acquistion of a spectral record.
For example, set REC_PRD = 0x020A (DIN = 0x9E0A, 0x9F02)
to set the trigger period to 10 hours.
Table 10. REC_PRD (Base Address = 0x1E), Read/Write
Bits
Description (Default = 0x0000)
[15:10]
Not used (don’t care)
[9:8]
Scale for data bits
00 = 1 second/LSB, 01 = 1 minute/LSB, 10 = 1 hour/LSB
[7:0]
Data bits, binary format; range = 0 to 255
Manual Time Capture Mode
Set REC_CTRL1[1:0] = 10 to place the device into manual time
capture mode; then use a manual trigger to start a data collection
cycle. When the device is operating in this mode, 512 samples
of time domain data are loaded into the buffer for each axis.
This data goes through all time domain signal processing, except
the pre-FFT windowing, prior to loading into the data buffer for
user access. The manual trigger options are the same as in the
manual FFT mode (SPI, I/O).
MEMS
ADC
PROCESSING
DATA
BUFFER
RECORDS
SPI AND
REGISTERS
Figure 13. Simplified Block Diagram



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com