Back Button ADIS16228/PCBZ Datasheet HTML 15Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 16Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 17Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 18Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 19Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 20Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 21Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 22Page - Analog Devices ADIS16228/PCBZ Datasheet HTML 23Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 19 / 28 page
background image
Data Sheet
ADIS16228
Rev. B | Page 19 of 28
ALARM STATUS
The ALM_x_STAT registers (see Table 37, Table 38, and Table 39)
provide alarm bits for each spectral band on the current sample
rate option.
Table 37. ALM_X_STAT (Base Address = 0x40), Read Only
Bits
Description (Default = 0x0000)
15
Alarm 2 on Band 6; 1 = alarm set, 0 = no alarm
14
Alarm 1 on Band 6; 1 = alarm set, 0 = no alarm
13
Alarm 2 on Band 5; 1 = alarm set, 0 = no alarm
12
Alarm 1 on Band 5; 1 = alarm set, 0 = no alarm
11
Alarm 2 on Band 4; 1 = alarm set, 0 = no alarm
10
Alarm 1 on Band 4; 1 = alarm set, 0 = no alarm
9
Alarm 2 on Band 3; 1 = alarm set, 0 = no alarm
8
Alarm 1 on Band 3; 1 = alarm set, 0 = no alarm
7
Alarm 2 on Band 2; 1 = alarm set, 0 = no alarm
6
Alarm 1 on Band 2; 1 = alarm set, 0 = no alarm
5
Alarm 2 on Band 1; 1 = alarm set, 0 = no alarm
4
Alarm 1 on Band 1; 1 = alarm set, 0 = no alarm
3
Not used
[2:0]
Most critical alarm condition, spectral band; range = 1 to 6
Table 38. ALM_Y_STAT (Base Address = 0x42), Read Only
Bits
Description (Default = 0x0000)
15
Alarm 2 on Band 6; 1 = alarm set, 0 = no alarm
14
Alarm 1 on Band 6; 1 = alarm set, 0 = no alarm
13
Alarm 2 on Band 5; 1 = alarm set, 0 = no alarm
12
Alarm 1 on Band 5; 1 = alarm set, 0 = no alarm
11
Alarm 2 on Band 4; 1 = alarm set, 0 = no alarm
10
Alarm 1 on Band 4; 1 = alarm set, 0 = no alarm
9
Alarm 2 on Band 3; 1 = alarm set, 0 = no alarm
8
Alarm 1 on Band 3; 1 = alarm set, 0 = no alarm
7
Alarm 2 on Band 2; 1 = alarm set, 0 = no alarm
6
Alarm 1 on Band 2; 1 = alarm set, 0 = no alarm
5
Alarm 2 on Band 1; 1 = alarm set, 0 = no alarm
4
Alarm 1 on Band 1; 1 = alarm set, 0 = no alarm
3
Not used
[2:0]
Most critical alarm condition, spectral band; range = 1 to 6
Table 39. ALM_Z_STAT (Base Address = 0x44), Read Only
Bits
Description (Default = 0x0000)
15
14
Alarm 2 on Band 6; 1 = alarm set, 0 = no alarm
Alarm 1 on Band 6; 1 = alarm set, 0 = no alarm
13
Alarm 2 on Band 5; 1 = alarm set, 0 = no alarm
12
Alarm 1 on Band 5; 1 = alarm set, 0 = no alarm
11
Alarm 2 on Band 4; 1 = alarm set, 0 = no alarm
10
Alarm 1 on Band 4; 1 = alarm set, 0 = no alarm
9
Alarm 2 on Band 3; 1 = alarm set, 0 = no alarm
8
Alarm 1 on Band 3; 1 = alarm set, 0 = no alarm
7
Alarm 2 on Band 2; 1 = alarm set, 0 = no alarm
6
Alarm 1 on Band 2; 1 = alarm set, 0 = no alarm
5
Alarm 2 on Band 1; 1 = alarm set, 0 = no alarm
4
Alarm 1 on Band 1; 1 = alarm set, 0 = no alarm
3
Not used
[2:0]
Most critical alarm condition, spectral band; range = 1 to 6
WORST-CASE CONDITION MONITORING
The ALM_x_PEAK registers (see Table 40, Table 41, and
Table 42) contain the peak magnitude for the worst-case alarm
condition in each axis. The ALM_x_FREQ registers (see Table 43,
Table 44, and Table 45) contain the frequency bin number for
the worst-case alarm condition.
Table 40. ALM_X_PEAK (Base Address = 0x46), Read Only
Bits
Description (Default = 0x0000)
[15:0]
Alarm peak, x-axis, accelerometer data format
Table 41. ALM_Y_PEAK (Base Address = 0x48), Read Only
Bits
Description (Default = 0x0000)
[15:0]
Alarm peak, y-axis, accelerometer data format
Table 42. ALM_Z_PEAK (Base Address = 0x4A), Read Only
Bits
Description (Default = 0x0000)
[15:0]
Alarm peak, z-axis, accelerometer data format
Table 43. ALM_X_FREQ (Base Address = 0x70), Read Only
Bits
Description (Default = 0x0000)
[15:8]
Not used
[7:0]
Alarm frequency for x-axis peak alarm level,
FFT bin number; range = 0 to 255
Table 44. ALM_Y_FREQ (Base Address = 0x72), Read Only
Bits
Description (Default = 0x0000)
[15:8]
Not used
[7:0]
Alarm frequency for y-axis peak alarm level,
FFT bin number; range = 0 to 255
Table 45. ALM_Z_FREQ (Base Address = 0x74), Read Only
Bits
Description (Default = 0x0000)
[15:8]
Not used
[7:0]
Alarm frequency for z-axis peak alarm level,
FFT bin number; range = 0 to 255



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com