| 数据搜索系统,热门电子元器件搜索 |
|
CS5490 数据表(PDF) 19 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5490 数据表(HTML) 19 Page - Cirrus Logic |
|
19 / 56 page ![]() CS5490 DS982F2 19 5.4 Line Frequency Measurement If the Automatic Frequency Calculation (AFC) bit in the Config2 register is set, the line frequency measurement on the voltage channel will be enabled. The line frequency measurement is based on a number of voltage channel zero crossings. This number is 100 by default and configurable through the ZXNUM register (see section 6.6.56 on page 50). The Epsilon register will be updated automatically with the line frequency information. The Frequency Update (FUP) bit in the Status0 interrupt status register is set when the frequency calculation is completed. When the line frequency is 50Hz and the ZXNUM register is 100, the Epsilon register is updated every one second with a resolution of less than 0.1%. A larger zero-crossing number in the ZXNUM register will increase line frequency measurement resolution and period. Note that the CS5490 line frequency measurement function does not support the line frequency out of the range of 40Hz to 75Hz. The Epsilon register is also used to set the gain of the 90° phase shift filter used in the quadrature power calculation. The value in the Epsilon register is the ratio of the line frequency to the output word rate (OWR). For 50Hz line frequency and 4000Hz OWR, Epsilon is 50/4000 (0.0125) (the default). For 60Hz line frequency, it is 60/4000 (0.015). 5.5 Energy Pulse Generation The CS5490 provides an independent energy pulse generation (EPG) block in order to output active, reactive, and apparent energy pulses on the digital output pin (DO). The energy pulse frequency is proportional to the magnitude of the power. The energy pulse output is commonly used as the test output of a power meter. The host microcontroller can also use the energy pulses to easily accumulate the energy. Refer to Figure 10. VZXLEVEL IZXLEVEL If |VPEAK| > VZXLEVEL, then voltage zero-crossing detection is enabled. If |IPEAK| > IZXLEVEL, then current zero-crossing detection is enabled. Zero-crossing output on DOx pin Pulse width = 250μs V( t), I(t) DO t t If |VPEAK| VZXLEVEL, then voltage zero-crossing detection is disabled. If |IPEAK| IZXLEVEL, then current zero-crossing detection is disabled. Figure 9. Zero-crossing Level and Zero-crossing Output on DO |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |