9 / 29 page ![]() Aeroflex Circuit Technology SCD7005 REV B 8/2/01 Plainview NY (516) 694-6700 9 command word be transferred to the RCV Command Register. This block of data is then burst (by the internal controller) into the corresponding internal RAM location, which is memory mapped by the subaddress contained in the RCV Command Register. Once this operation is complete, a discrete interrupt pulse called INT #1 is sent the subsystem. If this interrupt is used, the subsystem would read the command word from the RCV Command Register. The data could then be transferred to the OUTPUT FIFO buffer, and read by the subsystem. Each receive subaddress section of the internal RAM will contain only the most recent, valid, and complete block of data to that subaddress. This is true for Remote Terminal and Bus Controller operations. Transmit Commands If a valid transmit command is received, the command word is first loaded into the Command Word Register. The block of data corresponding to the subaddress of the transmit command is then transferred from the internal RAM to the XMIT FIFO buffer. Upon completion of this transfer, INT #2 is sent to the subsystem. The transmit section of the internal RAM is generally initialized at power up and periodically updated as required. Appropriate subsystem response to INT #2 for an RT implementation would be to read the command word from the Command Word Register. The data to this subaddress could now be refreshed in preparation for the next time it was requested to be transmitted across the 1553 bus. Mode Codes All 15 mode codes are serviced by the protocol section, and most do not require subsystem intervention. Discrete interrupt signals are available for each of the Synchronize (with and without data), Vector Word, Reset, and Dynamic Bus Control Acceptance mode codes. Mode command words are loaded into the Command Word Register. Separate registers are provided for the synchronize data word and the vector data words. Bus Control Operation Upon initialization of power to the ACT7005/6 Series, all registers are reset. The operation register is reset to FF80H; this setting defaults to the remote terminal mode of operation with the Busy Bit set. To enter into the Bus Control Mode of operation, bit 8 of the operation register must be asserted low. While in this mode, the upper byte (8 bits) of the operation register controls Bus Control functionality. This includes TEST/NORMAL operation, RT to RT commands, BUS selection and RETRY initialization of a faulty transaction. A typical Bus Control transaction would operate as follows: All areas of internal RAM that will be used for transmission are initialized by the subsystem with the desired data. To accomplish this, the subsystem will first WRITE to the INPUT buffer the number of words to be transferred. This information is now transferred to the internal RAM under control of the OPERATION register by specifying the subaddress bits 0-4, setting the T/R bit (bit 5) and l/O bit (bit 6) high. This will be executed by issuing an EXECUTE operation l/O command. When the transfer has been completed, the DONE interrupt will pulse low, and valid data will now reside in this RAM location. Next, the subsystem will write the command word to COMMAND WORD #1 register. If it were an RT-to-RT transfer, the transmitting RT command word would be written into COMMAND WORD #2 register. The next register to be intitialized would be the OPERATION register, which controls which bus to transmit on and if retry will be an option. This information will be enacted upon when the subsystem issues a TRIGGER I/O command. The return status word from the remote terminal or status words for RT-to-RT transfers will reside in their appropriate registers upon the issuance of INT #1. If the RETRY option had been selected and a valid transfer had not occurred, the RETRY interrupt would have occurred instead of INT #1. Three retrys are the maximum number allowed. The retrys can be accomplished on the primary or secondary bus determined by programming bits in the operation register. A retry will be initiated if the retry bits are set in the OPERATION register. The criteria for attempting a retry is the lack of a returned status word or returned mode data, or that 768µsec has transpired since the start of the data transfer. A retry will not be executed if bits are set in the return status word(s); this is up to the subsystem to interpret the status word contents and to reinitiate the transfer if desired. Discrete Interrupts Twelve discrete interrupt output signals are available for the subsystem interface. Any or all of these may be used depending on subsystem requirements. Excluding the signal BUFF EF, all interrupts are low going pulse signals. Interrupt and status signals RESET, DBCREQ, and NBGT are 500ns wide nominally, and VECTOR is typically 1.5µs wide. All remaining interrupts are nominally 160ns. The output buffer empty flag (BUFF EF), which is a level, is also made available for subsystem use. When low, it indicates the output buffer is empty. See Table 6 for additional information. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |