| 数据搜索系统,热门电子元器件搜索 |
|
L6470PD 数据表(PDF) 29 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6470PD 数据表(HTML) 29 Page - STMicroelectronics |
|
29 / 70 page ![]() L6470 Functional description Doc ID16737 Rev 5 29/70 expired and a GetStatus command is sent to the IC (see Section 9.1.22 and 9.1.17). The overcurrent event expires when all the Power MOSFET currents fall below the programmed overcurrent threshold. The overcurrent threshold can be programmed through the OCD_TH register in one of 16 available values ranging from 375 mA to 6 A with steps of 375 mA (see Table 9, Section 9.1.17). It is possible to set whether an overcurrent event causes or not the MOSFET turn-off (bridges in high impedance status) acting on the OC_SD bit in the CONFIG register (see Section 9.1.21). The OCD flag in the STATUS register is raised anyway (see Table 34, Section 9.1.22). When the IC outputs are turned off by an OCD event, they cannot be turned on until the OCD flag is released by a GetStatus command. Attention: The overcurrent shutdown is a critical protection feature. It is not recommended to disable it. 6.10 Undervoltage lockout (UVLO) The L6470 provides a motor supply UVLO protection. When the motor supply voltage falls below the VSthOff threshold voltage, the STATUS register UVLO flag is forced low. When a GetStatus command is sent to the IC, and the undervoltage condition has expired, the UVLO flag is released (see Section 9.1.22 and 9.2.20). The undervoltage condition expires when the motor supply voltage goes over the VSthOn threshold voltage. When the device is in undervoltage condition, no motion command can be performed. The UVLO flag is forced low by logic reset (power-up included) even if no UVLO condition is present. 6.11 Thermal warning and thermal shutdown An internal sensor allows the L6470 to detect when the device internal temperature exceeds a thermal warning or an overtemperature threshold. When the thermal warning threshold (Tj(WRN)) is reached, the TH_WRN bit in the STATUS register is forced low (see Section 9.1.22) until the temperature decreases below Tj(WRN) and a GetStatus command is sent to the IC (see Section 9.1.22 and 9.2.20). When the thermal shutdown threshold (Tj(OFF)) is reached, the device goes into thermal shutdown condition: the TH_SD bit in the STATUS register is forced low, the power bridges are disabled bridges in high impedance state and the HiZ bit in the STATUS register is raised (see Section 9.1.22). The thermal shutdown condition only expires when the temperature goes below the thermal warning threshold (Tj(WRN)). On exiting thermal shutdown condition, the bridges are still disabled (HiZ flag high); any motion command makes the device exit from High Z state (HardStop and SoftStop included). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |