| 数据搜索系统,热门电子元器件搜索 |
|
AD7654ASTZ 数据表(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7654ASTZ 数据表(HTML) 19 Page - Analog Devices |
|
19 / 28 page ![]() AD7654 Rev. B | Page 19 of 28 t1 t3 t4 t17 BUSY DATA BUS t16 NEW A OR B PREVIOUS CHANNEL A OR B PREVIOUS CHANNEL B OR NEW A t10 CS = RD = 0 EOC CNVST Figure 24. Master Parallel Data Timing for Continuous Read Slave Parallel Interface In slave parallel reading mode, the data can be read either after each conversion, which is during the next acquisition phase or during the other channel’s conversion, or during the following conversion, as shown in Figure 25 and Figure 26, respectively. When the data is read during the conversion, however, it is recommended that it is read only during the first half of the conversion phase. This avoids any potential feedthrough between voltage transients on the digital interface and the most critical analog conversion circuitry. DATA BUS t18 t19 BUSY CURRENT CONVERSION CS RD Figure 25. Slave Parallel Data Timing for a Read After Conversion PREVIOUS CONVERSION t1 t3 t18 t19 t4 BUSY DATA BUS t13 t11 t12 t10 CS =0 EOC CNVST, RD Figure 26. Slave Parallel Data Timing for a Read During Conversion 8-Bit Interface (Master or Slave) The BYTESWAP pin allows a glueless interface to an 8-bit bus. As shown in Figure 27, the LSB byte is output on D[7:0] and the MSB is output on D[15:8] when BYTESWAP is low. When BYTESWAP is high, the LSB and MSB bytes are swapped, the LSB is output on D[15:8], and the MSB is output on D[7:0]. By connecting BYTESWAP to an address line, the 16-bit data can be read in two bytes on either D[15:8] or D[7:0]. BYTESWAP PINS D[15:8] PINS D[7:0] HI-Z HI-Z HIGH BYTE LOW BYTE LOW BYTE HIGH BYTE HI-Z HI-Z t18 t18 t19 CS RD Figure 27. 8-Bit Parallel Interface Channel A/B Output The A/B input controls which channel’s conversion results (INAx or INBx) are output on the data bus. The functionality of A/B is detailed in Figure 28. When high, the data from Channel A is available on the data bus. When low, the data from Channel B is available on the bus. Note that Channel A can be read immediately after conversion is done (EOC), while Channel B is still in its converting phase. However, in any of the serial reading modes, Channel A data is updated only after Channel B is converted. t18 t20 CS DATA BUS RD HI-Z A/B HI-Z CHANNEL A CHANNEL B Figure 28. A/B Channel Reading |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |