| 数据搜索系统,热门电子元器件搜索 |
|
ADM1275-1ACPZ-R7 数据表(PDF) 42 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1275-1ACPZ-R7 数据表(HTML) 42 Page - Analog Devices |
|
42 / 48 page ![]() ADM1275 Data Sheet Rev. D | Page 42 of 48 Byte Byte Name Value Description 9 Character 9 0x31 or “1” Always reads as 0x31 on the ADM1275-1. 0x32 or “2” Always reads as 0x32 on the ADM1275-2. 0x33 or “3” Always reads as 0x33 on the ADM1275-3. MFR_REVISION Code: 0x9B, block read. Value after reset: 0x01 + ASCII “1”. Table 32. Bit Descriptions for MFR_REVISION Command Byte Byte Name Value Description 0 Byte count 0x01 Always reads as 0x01, the number of data bytes that the block read command should expect to read. 1 Character 1 0x31 or “1” Always reads as 0x31, Revision 1 of the ADM1275. PEAK_IOUT Code: 0xD0, read/write word. Value after reset: 0x0000 (writing 0x0000 clears the peak value). Table 33. Bit Descriptions for PEAK_IOUT Command Bits Bit Name Settings Description [15:12] Reserved 0000 Always reads as 0000. [11:0] PEAK_IOUT Returns the peak IOUT current since the register was last cleared. PEAK_VIN Code: 0xD1, read/write word. Value after reset: 0x0000 (writing 0x0000 clears the peak value). Table 34. Bit Descriptions for PEAK_VIN Command Bits Bit Name Settings Description [15:12] Reserved 0000 Always reads as 0000. [11:0] PEAK_VIN Returns the peak VIN voltage since the register was last cleared. PEAK_VOUT Code: 0xD2, read/write word. Value after reset: 0x0000 (writing 0x0000 clears the peak value). This command is supported on the ADM1275-1 and the ADM1275-3. The ADM1275-2 does not have a VOUT pin. Table 35. Bit Descriptions for PEAK_VOUT Command Bits Bit Name Settings Description [15:12] Reserved 0000 Always reads as 0000. [11:0] PEAK_VOUT Returns the peak VOUT voltage since the register was last cleared. PMON_CONTROL Code: 0xD3, read/write byte. Value after reset: 0x00. Table 36. Bit Descriptions for PMON_CONTROL Command Bits Bit Name Settings Description [7:1] Reserved 0000000 Always reads as 0000000. 0 CONVERT 0 Default. Power monitor is not running. 1 Start the sampling of current and voltage with the power monitor. In single-shot mode, this bit clears itself after one complete cycle. In continuous mode, this bit must be written to 0 to stop sampling. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |