| 数据搜索系统,热门电子元器件搜索 |
|
INA226AIDGST 数据表(PDF) 16 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
INA226AIDGST 数据表(HTML) 16 Page - Texas Instruments |
|
16 / 33 page ![]() Current BusVoltage 20,000 · Power = Corrected_Full_Scale_Cal = trunc Cal MeasShuntCurrent INA226_Current ´ INA226 SBOS547 – JUNE 2011 www.ti.com The Power Register (03h) is then be calculated by multiplying the decimal value of the Current Register, 10000, by the decimal value of the Bus Voltage Register, 9584, and then dividing by 20,000, as defined in Equation 4. For this example, the result for the Power Register is 12B8h, or a decimal equivalent of 4792. Multiplying this result by the power LSB (25 times the [1 × 10–3 Current LSB]) results in a power calculation of (4792 × 25mW/bit), or 119.82W. The power LSB has a fixed ratio to the current LSB of 25W/bit to 1A/bit. For this example, a programmed 1mA/bit current LSB results in a power LSB of 25mW/bit. This ratio is internally programmed to ensure that the scaling of the power calculation is within an acceptable range. A manual calculation for the power being delivered to the load would use a bus voltage of 11.98V (12VCM – 20mV shunt drop) multiplied by the load current of 10A to give a result of 119.8W. (4) Table 1 shows the steps for configuring, measuring, and calculating the values for current and power for this device. Table 1. Configure/Measure/Calculate Example(1) STEP # REGISTER NAME ADDRESS CONTENTS DEC LSB VALUE Step 1 Configuration 00h 4127h — — — Step 2 Shunt 01h 1F40h 8000 2.5 µV 20mV Step 3 Bus 02h 2570h 9584 1.25mV 11.98V Step 4 Calibration 05h A00h 2560 — — Step 5 Current 04h 2710 10000 1mA 10A Step 6 Power 03h 12B8h 4792 25mW 119.82W (1) Conditions: Load = 10A, VCM = 12V, RSHUNT = 2mΩ, and VBUS = 12V. PROGRAMMING THE INA226 POWER MEASUREMENT ENGINE Calibration Register and Scaling The Calibration Register makes it possible to set the scaling of the Current and Power Registers to whatever values are most useful for a given application. One strategy may be to set the Calibration Register such that the largest possible number is generated in the Current Register or Power Register at the expected full-scale point. This approach would yield the highest resolution based using the previously calculated minimum current LSB in the equation for the Calibration Register. The Calibration Register can also be selected to provide values in the Current and Power Registers that either provide direct decimal equivalents of the values being measured, or yield a round LSB value for each corresponding register. After these choices have been made, the Calibration Register also offers possibilities for end user system-level calibration. By physically measuring the current with an external ammeter, the exact current is known. The value of the Calibration Register can then be adjusted based on the measured current result of the INA226 to cancel the total system error as shown in Equation 5. (5) 16 Submit Documentation Feedback Copyright © 2011, Texas Instruments Incorporated Product Folder Link(s): INA226 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |