| 数据搜索系统,热门电子元器件搜索 |
|
H7CX-R11W-N 数据表(PDF) 15 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CX-R11W-N 数据表(HTML) 15 Page - Omron Electronics LLC |
|
15 / 56 page ![]() H7CX-A @-N 15 Counter Operating Procedures Setting Procedure Guide Setting for Counter Operation * Use the following settings. Setting for Tachometer Operation * Refer to page page 27. * At the time of delivery, the H7CX is set to the 1-stage preset counter configuration. (2-stage models are set to the 2-stage preset counter configuration.) Refer to page page 35 for information on switching models. I/O Functions for Counter Operation After making DIP switch settings for basic operations, advanced functions can be added using the operation keys. For details, refer to page page 16. Key-protect switch Disabled Enabled OFF ON OFF ON OFF OFF ON ON N F C K-1 UP DOWN Refer to the table on the right. 30 Hz 5 kHz 20 ms 1 ms DIP switch settings Counting speed Input mode Output mode Minimum reset signal Input selection Output time 0.5 s 0.05 s NPN PNP Note: All pins are factory-set to OFF. • When setting functions using the DIP switch, be sure to set pin 1 of the DIP switch to ON. • DIP switch settings are effective when the power is turned ON again. (Perform DIP switch settings while the power is OFF.) Step1 Step3 Set the basic parameters. (If the desired I/O mode is not listed below or to set all parameters using the front panel keys, perform , below.) Note: can be performed first, followed by . Note: The configuration that can be selected depends on the model. * The default mode is 1-stage preset counter configuration (2-stage preset counter configuration for 2-stage models). Item OFF ON Output mode Pin 5 Pin 4 1 2 3 4 5 6 7 8 Step2 Step2 Step1 Hold down for 1 s min. Select the function from Table 1 using the U (D) Key. Run mode Power ON 1 + Hold down for 1 s min. 1 + twn The H7CX-A @-N is a Counter that contains more than one functional counter. When using the Counter in any mode other than the default mode*, use the following chart to enter Configuration Selection Mode and set the functions that are suitable to the application. (1-stage preset counter) (2-stage preset counter) (Total and preset counter) (Batch counter) (Dual counter) (Twin counter) (Tachometer) Configuration selection mode Be sure to set pin 1 to ON. OFF ON 12345678 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |