45 / 56 page ![]() H7CX-R @-N 45 Explanation of Functions Basic Functions Input Mode The mode can be switched between tachometer mode and AMD- compatible mode. Tachometer Mode Use this mode to measure the pulse frequency (Hz). AMD-compatible Mode Use this mode to measure the pulse cycle (s). Counting Speed Set the maximum counting speed (30 Hz/10 kHz) for input. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for this setting. Output Mode Set the output method for control output based on the comparison value. Upper and lower limit (HI-LO), area (AREA), upper limit (HI), and lower limit (LO) can be set. For the H7CX-RW @, the upper limit (HI- HI) and lower limit (LO-LO) can be set. (For details on the operation of the output modes, refer to Output Mode Settings on page page 49.) Averaging Method ( avgt) Simple averaging or a moving average can be selected for the averaging method. With a moving average, the average measurement value is displayed every sampling cycle or pulse cycle, in contrast to simple averaging, for which the average value is displayed for the set number of samples. Number of Averaging Times Flickering display and output chattering can be prevented using average processing. Average processing can be set to one of four levels: no average processing, 2 times (i.e., the average of 2 measurement values), 4 times, or 8 times. For a measurement frequency of 5 Hz or higher using a tachometer, the average will be equal to the sampling cycle (200 ms) multiplied by the averaging setting (i.e., the number of times). For less than 5 Hz, the frequency will be measured when the input pulse comes. Average processing produces a stable display even for fluctuating input signals. Set the optimum number of times for the application. If AMD-compatible mode is used, the measurement cycle will be measured when the input pulse is received. The output will change, however, when the comparison value is exceeded even if averaging is enabled. NPN/PNP Input Mode Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. When using a two-wire sensor, select NPN input. The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page page 40. Advanced Functions Decimal Point Position ( dp) Decide the decimal point position for the measurement value and comparison value. Prescale Value ( pscl) It is possible to display the rate of rotation or the speed of a device or machine to which the H7CX is mounted by converting input pulses to a desired unit. If the default prescaling value (1,000) is used, the input frequency (Hz) will be displayed. The relationship between display and input is determined by the following equation. Set the prescale value according to the unit to be displayed. Displayed value = f × α f: Input pulse frequency (number of pulses in 1 second) α: Prescale value (1) Displaying Rotation Rate N: Number of pulses per revolution Example: In order to display the rate of rotation for a machine that outputs 5 pulses per revolution in the form @@.@ rpm: 1. Set the decimal point position to 1 decimal places. 2. Using the formula, set the prescale value ( α) to 1/N × 60 = 60/5 = 12. (2) Displaying Speed N: Number of pulses per revolution d: Diameter of rotating body (m) πd: Circumference (m) • Observe the following points when setting a prescale value. Set the set value to a value less than {Maximum countable value − Prescale value}. Example: If the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 − 1.25). If the set value is set to a value greater than this, output will not turn ON. Auto-zero Time ( auto0) It is possible to make the settings so that the frequency will be force- set to 0 if there is no pulse for a specified period of time. This time is called the auto-zero time. Cycle (s) Display unit Prescale value ( α) rpm 1/N × 60 rps 1/N Display unit Prescale value ( α) m/min πd × 1/N × 60 m/s πd × 1/N d: Diameter of rotating body (m) Note: If the prescale value setting is incorrect, a counting error will occur. Check that the settings are correct before using this function. Note: Set the auto-zero time to a time slightly longer than the estimated interval between input pulses. It will not be possible to make accurate measurements if the auto-zero time is set to a time shorter than the input pulse cycle. Setting a time that is too long may also result in problems, such as a time-lag between rotation stopping and the alarm turning ON. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |