35 / 56 page ![]() H7CX-A @-N 35 Switching between Preset Counter, Total and Preset Counter, Batch Counter, Dual Counter, Twin Counter, and Tachometer Operation Select which H7CX configuration is used (i.e., preset counter, total and preset counter, batch counter, dual counter, twin counter, or tachometer) in configuration selection mode. The H7CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the display on the front of the H7CX. Hold Function The measurement value (display value) and output are sustained while the hold input is ON. Note: The output will maintain the current status when the hold key is pressed. Example: Output mode setting Operation Lower limit 1 + 1 1 RST bcnt dcnt taco twn 1cnt 2cnt tcnt Key Key Key Key …Indicates that DIP switch pin 8 is ON. …Indicates that DIP switch pin 7 is OFF. …Indicates that DIP switch pin 6 is ON. …Indicates that DIP switch pin 5 is OFF. …Indicates that DIP switch pin 4 is ON. …Indicates that DIP switch pin 3 is OFF. …Indicates that DIP switch pin 2 is ON. …Indicates that DIP switch pin 1 is ON. *The configurations that can be selected depend on the model. Press the key for 1 s min. *1 When the mode is changed to configuration selection mode, the present value is reset, outputs turn OFF, and counting (measuring) stops. *2 Setting changes made in configuration selection mode are enabled when the mode is changed to run mode. If the configuration is changed, the set value (or set value 1 and set value 2), comparison value 1 and comparison value 2 are initialized. Power ON Example Configuration selection Note DIP switch monitor (DIP) Con venient *2 *1 *This display is possible only when DIP switch pin 1 (DIP switch settings enable/disable) is set to ON (enable). Select the configuration using the UD Key. 1 1 To change the mode to configuration selection mode, hold down the Key for 1 s min. with the Key held down. The mode will not change if the Key is pressed first. (1-stage preset counter) (2-stage preset counter) (Total and preset counter) (Batch counter) (Dual counter) (Twin counter) (Tachometer) Note: By default, the H7CX is set to the 1-stage preset counter configuration. (Two-stage models are set to the 2-stage preset counter configuration.) Confirm the status of DIP switch pins 1 to 8 using the UD Key. OFF ON 12345678 OUT Display value Hold input* (Reset Key) Comparison value (lower limit) Sustained display value Sustained output Actual input |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |