| 数据搜索系统,热门电子元器件搜索 |
|
H7CX-R11W-N 数据表(PDF) 44 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CX-R11W-N 数据表(HTML) 44 Page - Omron Electronics LLC |
|
44 / 56 page ![]() 44 H7CX-R @-N (99.9 s) (0.0 s) (Enabled) (Disabled) (99999) (0) (19.99 s) (0.00 s) (999999) (1) (999.9 s) (0.1 s) kp-1 off on 0 99999 0.00 19.99 999999 1 kp-2 kp-3 kp-4 kp-5 kp-6 kp-7 0 9999 0 9999 0 9999 Procedure for Models Other than “-R11W @” Models Procedure for “-R11W @” Models (9999 × 1000 times) (0 × 1000 times) (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) (KP-6) (KP-7) *1 Note: Not displayed in AMD-compatible mode. *1 Set each digit using the individual U Key. Note: The monitor value is only displayed. It cannot be set. Output OFF delay (OFFD) Output ON count alarm set value/monitor value • Set each digit using the individual U Key. Auto-zero time (AUTO0) Startup time (STMR) Peak/bottom hold enabled (DHLD) Output hysteresis (HYS) Set value upper limit (SL-H) Key protect level (KYPT) • Set each digit using the individual U Key. • Enable or disable peak/bottom hold using the U Key. • Set the output hysteresis using the U Key. • Set each digit using the individual U Key. Note: The measurement value after prescaling is set. • Set each digit using the individual U Key. • Set the key protect level using the U Key. Output ON count alarm set value Output ON count monitor value Output 1 (OUT1) ON count alarm set value Output 2 (OUT2) ON count alarm set value Note: The monitor value is only displayed. It cannot be set. Note: The monitor value is only displayed. It cannot be set. Output 1 (OUT1) ON count monitor value Output 2 (OUT2) ON count monitor value (9999 × 1000 times) (0 × 1000 times) (9999 × 1000 times) (0 × 1000 times) (MV) (SMP) (99.999) (1.000) (0.001) The characters displayed in reverse video are the default settings. smp mv Power ON Run mode Step2 Change to Function Setting Mode. 3 s min.*2 3 s min.*1 • Set the decimal point position using the U Key. *1 If the mode is switched to the function setting mode during operation, operation will continue. *2 Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the counter is reset (measured values initialized and output turned OFF) on returning to run mode. Function setting mode Averaging method (AUGT) Prescale value (PSCL) Decimal point position (DP) (No decimal point) (One digit after decimal point) (Two digits after decimal point) (Three digits after decimal point) • Set each digit using the individual U Key. • Set the averaging method using the U Key. Note: Not displayed in AMD-compatible mode. For details on operations in run mode, refer to page page 47. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |