| 数据搜索系统,热门电子元器件搜索 |
|
CLC030 数据表(PDF) 10 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
CLC030 数据表(HTML) 10 Page - National Semiconductor (TI) |
|
10 / 29 page ![]() Device Operation (Continued) pendent of the video data clock, VCLK. Inputs AD[9:0], RD/WR and ANC/CTRL have internal pull down devices. ACLK does not have an internal pull down device. Control Data Read Functions Control data is input to and output from the CLC030 using the lower-order 8 bits AD[7:0] of the Ancilliary/Control Data Port. This control data initializes, monitors and controls op- eration of the CLC030. The upper two bits AD[9:8] of the port function as handshaking signals with the device access- ing the port. AD[9:8] must be driven as 00b (0XXh, where XX are AD[7:0]) when either a control register read or write address is being written to the port. AD[9:8] must be driven as 11b (3XXh, where XX are AD[7:0]) when control data is being written to the port. When control data is being read from the port, the CLC030 will output AD[9:8] as 10b (2XXh, where XX are output data AD[7:0]) and may be ignored by the monitoring system. Note: When power is first applied to the device or after it is reset, the Ancilliary and Control Data Port must be initial- ized to receive data. This is done by toggling ACLK three (3) times. Figure 1 shows the sequence of clock and control signals for reading control data from the ancilliary/control data port. Control data read mode is invoked by making the ANC/CTRL input low and the RD/WR input high. The 8-bit address of the control register set to be accessed is input to the port on bits AD[7:0]. The address is captured on the rising edge of ACLK. When a control register read address is being written to the port, AD[9:8] must be driven as 00b (0XXh, where XX are AD[7:0]). When control data is being read from the port, the CLC030 will output AD[9:8] as 10b (2XXh, where XX are output data AD[7:0]) and may be ignored by the monitoring system. Data being output from the selected register is driven by the port immediately follow- ing the rising edge of ACLK or when the address signals are removed. For optimum system timing, the address signals driving the port should be removed immediately after the address is clocked into the device and before or coincident with the falling edge of ACLK at the end of the address cycle. Output data remains stable until the next rising edge of ACLK and may be read by external devices at any time after the removal of the address signal. This second clock resets the port from drive to receive mode and readies the port for another access cycle. Example: Read the Full-field Flags via the AD port. 1. Set ANC/CTRL to a logic-low. 2. Set RD/WR to a logic-high. 3. Present 001h to AD[9:0] as the register address. 4. Toggle ACLK. 5. Release the bus driving the AD port. 6. Read the data present on the AD port. The Full-field Flags are bits AD[4:0]. 7. Toggle ACLK to release the AD port. Control Data Write Functions Figure 2 shows the sequence of clock and control signals for writing control data to the ancilliary/control data port. The control data write mode is similar to the read mode. Con- trol data write mode is invoked by making the ANC/CTRL input low and the RD/WR input low. The 8-bit address of the control register set to be accessed is input to the port on bits AD[7:0]. The address is captured on the rising edge of ACLK. The address data is removed after being clocked into the device or before the falling edge of ACLK. Next, the control data is presented to the port bits AD[7:0] and written into the selected register on the next rising edge of ACLK. When a control register write address is being written to the port, AD[9:8] must be driven as 00b (0XXh, where XX are AD[7:0]). When control data is being written to the port, AD[9:8] must be driven as 11b (3XXh, where XX are AD[7:0]). Control data written into the registers may be read out non-destructively in most cases. Example: Setup (without enabling) the TPG Mode via the AD port using the 1125 line, 30 frame, 74.25MHz, interlaced component (SMPTE 274M) colour bars as test pattern. The TPG may be enabled after setup using the Multi-function I/O port or by the control registers. 1. Set ANC/CTRL to a logic-low. 2. Set RD/WR to a logic-low. 3. Present 00Dh to AD[9:0] as the Test 0 register address. 4. Toggle ACLK. 5. Present 027h to AD[9:0] as the register data. 6. Toggle ACLK. www.national.com 10 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |