19 / 44 page ![]() REV. PrG 01/03 PRELIMINARY TECHNICAL DATA ADE7754 – 19 – ACTIVE POWER CALCULATION Electrical power is defined as the rate of energy flow from source to load. It is given by the product of the voltage and current waveforms. The resulting waveform is called the instantaneous power signal and it is equal to the rate of energy flow at every instant of time. The unit of power is the watt or joules/sec. Equation 5 gives an expression for the instanta- neous power signal in an ac system. v(t) t = 2V sin( ) ω (3) i(t) t = 2I sin( ) ω (4) where V = rms voltage, I = rms current. p(t) v(t) i(t) = × p(t) 2 t = VI - VI cos( ) ω (5) The average power over an integral number of line cycles (n) is given by the expression in Equation 6. P = 1 nT p(t)dt=VI 0 nT ∫ (6) where T is the line cycle period. P is referred to as the Active or Real Power. Note that the active power is equal to the DC component of the instanta- neous power signal p(t) in Equation 5 , i.e., VI. This is the relationship used to calculate active power in the ADE7754 for each phase. The instantaneous power signal p(t) is generated by multiplying the current and voltage signals in each phase. The DC component of the instantaneous power signal in each phase (A, B and C) is then extracted by LPF2 (Low Pass Filter) to obtain the active power information on each phase. This process is illustrated graphically on Figure 20. In a polyphase system, the total electrical power is simply the sum of the real power in all active phases. The different solutions available to process the total active power are discussed in the following paragraph. Voltage Current Instantaneous Power Signal Active Real Power Signal = V x I V. I. 00000h 1A36E2Eh D1B717h ) sin( 2 t I i(t) ω = ) sin( 2 t V v(t) ω = ) 2 cos( t I V I V p(t) ω × − × = Figure 20– Active Power Calculation Voltage RMS Gain Adjust The Voltage Gain register (AVGAIN[11:0], BVGAIN and CVGAIN) have an effect on the Apparent Power and voltage rms values. It is not recommended to calibrate the voltage rms measurements with these registers. The conversion of the voltage rms registers values to Volts has to be done in an external Micro-controller with a specific Volt/LSB constant for each phase - see Calibration of a 3-phase meter based on the ADE7754. Due to gain mismatches between phases, the calibration of the Volt/LSB constant has to be done for each phase separately. One point calibration is sufficient for this calibration. The Voltage Gain registers are aimed to ease the calibration of the apparent energy calculation in MODE 1 and 2 of the VAMODE register. If the VGAIN registers are used for Apparent Power calibra- tion (VAMOD bits in VAMode register = 1 or 2), the voltage rms values are changed by Voltage Gain register value as described in the expression below: Voltage RMS gister Phase A RMS AVGAIN Re =× + 1 2 12 For example, when 7FFh is written to the Voltage Gain register, the ADC output is scaled up by +50%. 7FFh = 2047d, 2047/2 12 = 0.5. Similarly, 800h = -2047 Dec (signed 2’s Complement) and ADC output is scaled by –50%. These two examples are illustrated graphically in Figure 19. Voltage RMS offset compensation The ADE7754 incorporates a voltage RMS offset compen- sation for each phase (AVRMSOS, BVRMSOS and CVRMSOS). These are 12-bit 2-complement signed regis- ters which can be used to remove offsets in the voltage RMS calculations. An offset may exist in the RMS calculation due to input noises and offsets in the input samples. The offset calibration allows the contents of the VRMS registers to be maintained at zero when no voltage is applied. n LSB of the Voltage RMS offset are equivalent to 64 x n LSB of the voltage RMS register. Assuming that the maximum value from the Voltage RMS calculation is 1,898,124d with full scale AC inputs, then 1 LSB of the voltage RMS offset represents 0.07% of measurement error at -26dB down of full scale. V V VRMSOS rms rms =+ × 0 64 where Vrmso is the RMS measurement without offset correc- tion. The voltage rms offset compensation should be done by testing the rms results at two non-zero input levels. One measurement can be done close to full scale and the other at approximately Full scale/10. The voltage offset compensa- tion can then be derived from these measurements - see Calibration of a 3-phase meter based on the ADE7754. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |