| 数据搜索系统,热门电子元器件搜索 |
|
QS5.DNET 数据表(PDF) 14 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
QS5.DNET 数据表(HTML) 14 Page - PULS GmbH |
|
14 / 21 page ![]() QS5.DNET Q-Series 24V, 3.8A, NEC CLASS 2, DEVICENET® POWER SUPPLY 16. PROTECTION FEATURES Output protection Electronically protected against overload, no-load and short-circuits *) Output over-voltage protection typ. 27Vdc max. 29Vdc In case of an internal power supply defect, a redundant circuit limits the maximum output voltage. The output shuts down and automatically attempts to restart. Degree of protection IP 20 EN/IEC 60529 Penetration protection > 3.5mm e.g. screws, small parts Over-temperature protection yes Output shut-down with automatic restart Input transient protection MOV (Metal Oxide Varistor) Internal input fuse T3.15A H.B.C. not user replaceable *) In case of a protection event, audible noise may occur. 17. SAFETY FEATURES Input / output separation *) SELV IEC/EN 60950-1 PELV IEC/EN 60204-1, EN 50178, IEC 62103, IEC 60364-4-41 Class of protection I PE (Protective Earth) connection required Isolation resistance > 5MOhm input to output, 500Vdc PE resistance < 0.1Ohm Touch current (leakage current) typ. 0.11mA / 0.28mA 100Vac, 50Hz, TN-,TT-mains / IT-mains typ. 0.16mA / 0.4mA 120Vac, 60Hz, TN-,TT-mains / IT-mains typ. 0.27mA / 0.68mA 230Vac, 50Hz, TN-,TT-mains / IT-mains < 0.14mA / 0.33mA 110Vac, 50Hz, TN-,TT-mains / IT-mains < 0.22mA / 0.49mA 132Vac, 60Hz, TN-,TT-mains / IT-mains < 0.40mA / 0.88mA 264Vac, 50Hz, TN-,TT-mains / IT-mains *) double or reinforced insulation 18. DIELECTRIC STRENGTH The output voltage is floating and has no ohmic connection to the ground. Type and factory tests are conducted by the manufacturer. Field tests may be conducted in the field using the appropriate test equipment which applies the voltage with a slow ramp (2s up and 2s down). Connect all input-terminals together as well as all output poles before conducting the test. When testing, set the cut-off current settings to the value in the table below. Fig. 18-1 Dielectric strength A B C D Type test 60s 2500Vac 3000Vac 500Vac 500Vac Factory test 5s 2500Vac 2500Vac 500Vac 500Vac Field test 5s 2000Vac 2000Vac 500Vac 500Vac Cut-off current setting > 10mA > 10mA > 20mA > 1mA AD C B N L Input DC-ok Earth, PE Output - + To fulfil the PELV requirements according to EN60204-1 § 6.4.1, we recommend that either the + pole, the – pole or any other part of the output circuit shall be connected to the protective earth system. This helps to avoid situations in which a load starts unexpectedly or can not be switched off when unnoticed earth faults occur. Mar. 2013 / Rev. 2.2 DS-QS5.DNET-EN All parameters are specified at 24V, 3.8A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 14/21 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |