| 数据搜索系统,热门电子元器件搜索 |
|
QS5.DNET 数据表(PDF) 19 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
QS5.DNET 数据表(HTML) 19 Page - PULS GmbH |
|
19 / 21 page ![]() QS5.DNET Q-Series 24V, 3.8A, NEC CLASS 2, DEVICENET® POWER SUPPLY 24.3. EXTERNAL INPUT PROTECTION The unit is tested and approved for branch circuits up to 30A (UL) and 32A (IEC). An external protection is only required if the supplying branch has an ampacity greater than this. Check also local codes and local requirements. In some countries local regulations might apply. If an external fuse is necessary or utilized, minimum requirements need to be considered to avoid nuisance tripping of the circuit breaker. A minimum value of 6A B- or 3A C-Characteristic breaker should be used 24.4. CHARGING OF BATTERIES The power supply can not be used to charge any kind of batteries since the output voltage adjustment range is too small. 24.5. OUTPUT CIRCUIT BREAKERS Standard miniature circuit breakers (MCB’s or UL1077 circuit breakers) are commonly used for AC-supply systems and may also be used on 24V branches. MCB’s are designed to protect wires and circuits. If the ampere value and the characteristics of the MCB are adapted to the wire size that is used, the wiring is considered as thermally safe regardless of whether the MCB opens or not. To avoid voltage dips and under-voltage situations in adjacent 24V branches which are supplied by the same source, a fast (magnetic) tripping of the MCB is desired. A quick shutdown within 10ms is necessary corresponding roughly to the ride-through time of PLC's. This requires power supplies with high current reserves and large output capacitors. Furthermore, the impedance of the faulty branch must be sufficiently small in order for the current to actually flow. The best current reserve in the power supply does not help if Ohm’s law does not permit current flow. The following table has typical test results showing which B- and C-Characteristic MCBs magnetically trip depending on the wire cross section and wire length. Fig. 24-3 Test circuit Maximal wire length*) for a fast (magnetic) tripping: 0.75mm² 1.0mm² 1.5mm² 2.5mm² C-2A 14m 18m 24m 43m C-3A 9m 13m 21m 31m C-4A 3m 4m 6m 9m C-6A - - - 1m B-6A 4m 7m 9m 11m MCB Power Supply AC DC + - + - Load Wire length S1... Fault simulation switch S1 *) Don’t forget to consider twice the distance to the load (or cable length) when calculating the total wire length (+ and – wire). Mar. 2013 / Rev. 2.2 DS-QS5.DNET-EN All parameters are specified at 24V, 3.8A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 19/21 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |