| 数据搜索系统,热门电子元器件搜索 |
|
ST7MC1K2 数据表(PDF) 248 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST7MC1K2 数据表(HTML) 248 Page - STMicroelectronics |
|
248 / 371 page ![]() Obsolete Product(s) - Obsolete Product(s) On-chip peripherals ST7MC1K2-Auto, ST7MC1K6-Auto, ST7MC2S4-Auto, ST7MC2S6-Auto 248/371 Figure 115. Channel manager output block diagram with PWM generator delivering three PWM signals 1. The output of the current limitation comparator can be used when three PWM signals are enabled if the VOC1 bit = 0 in the MCRA register. If the PCN bit is reset, one of the three PWM signals (the one set by the compare U register pair) or the output of the measurement window generator (depending on if the driving mode is voltage or current) is used to provide six-step signals through the PWM manager (to drive a PM BLDC motor for instance). In that case, DTE behaves like a standard bit (with multiple write capability). When the deadtime generator is enabled (bit DTE = 1), the following restrictions are applied: ● Channels are now grouped by pairs: channel[0:1], channel[2:3], channel[4:5]; a deadtime generator is allocated to each of these pairs (see cautions below). ● The input signal of the deadtime generator is the active output of the PWM manager for the corresponding channel. For instance, if we consider the channel[0:1] pair, it may be either channel 0 or channel 1. ● When both channels of a pair are inactive, the corresponding outputs also stay inactive (this is mandatory to allow BEMF zero-crossing detection). These restrictions are summarized in Table 111, which also summarizes the functionality of the deadtime generator when the PCN bit is reset. 1 (PWM) means that the corresponding channel is active (1 in the corresponding bit in the MPHST register), and a PWM signal is applied on it (using the MPAR register and the OS[2:0] bits in MCRB register). PWM represents the complementary signals (although the duty cycle is slightly different due to deadtime insertion). 0 means that the channel is inactive and 1 means that the channel is active and a logic level 1 is applied on it (no PWM signal). Dead time 8 MDTG register U V W PWM generator signals PCN bit = 1 OP[5:0] bits MOE bit x6 x6 6 1 MPOL register MRCA register Channel [1:0] Channel [3:2] Channel [5:4] 2 High frequency chopper HFE[1:0] bits HFRQ[2:0] bits MREF register 5 CLI bit CLIM bit OCV bit 1 1 1 Dead time Dead time Obsolete Product(s) - Obsolete Product(s) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |