| 数据搜索系统,热门电子元器件搜索 |
|
STM32F401CD 数据表(PDF) 65 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STM32F401CD 数据表(HTML) 65 Page - STMicroelectronics |
|
65 / 135 page ![]() DocID025644 Rev 3 65/135 STM32F401xD STM32F401xE Electrical characteristics 114 6.3.6 Supply current characteristics The current consumption is a function of several parameters and factors such as the operating voltage, ambient temperature, I/O pin loading, device software configuration, operating frequencies, I/O pin switching rate, program location in memory and executed binary code. The current consumption is measured as described in Figure 19: Current consumption measurement scheme. All the run-mode current consumption measurements given in this section are performed with a reduced code that gives a consumption equivalent to CoreMark code. Typical and maximum current consumption The MCU is placed under the following conditions: • All I/O pins are in input mode with a static value at VDD or VSS (no load). • All peripherals are disabled except if it is explicitly mentioned. • The Flash memory access time is adjusted to both fHCLK frequency and VDD ranges (refer to Table 15: Features depending on the operating power supply range). • The voltage scaling is adjusted to fHCLK frequency as follows: – Scale 3 for fHCLK ≤ 60 MHz – Scale 2 for 60 MHz < fHCLK ≤ 84 MHz • The system clock is HCLK, fPCLK1 = fHCLK/2, and fPCLK2 = fHCLK. • External clock is 4 MHz and PLL is on • The maximum values are obtained for VDD = 3.6 V and a maximum ambient temperature (TA), and the typical values for TA= 25 °C and VDD = 3.3 V unless otherwise specified. IRUSH(2) InRush current on voltage regulator power- on (POR or wakeup from Standby) - 160 200 mA ERUSH(2) InRush energy on voltage regulator power- on (POR or wakeup from Standby) VDD = 1.7 V, TA = 105 °C, IRUSH = 171 mA for 31 µs -- 5.4 µC 1. The product behavior is guaranteed by design down to the minimum VPOR/PDR value. 2. Guaranteed by design, not tested in production. 3. The reset timing is measured from the power-on (POR reset or wakeup from VBAT) to the instant when first instruction is fetched by the user application code. Table 19. Embedded reset and power control block characteristics (continued) Symbol Parameter Conditions Min Typ Max Unit |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |