| 数据搜索系统,热门电子元器件搜索 |
|
AD9957/PCBZ 数据表(PDF) 37 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9957/PCBZ 数据表(HTML) 37 Page - Analog Devices |
|
37 / 62 page ![]() AD9957 Data Sheet Rev. E | Page 36 of 61 PLL CHARGE PUMP The charge pump current (ICP) is programmable to provide the user with additional flexibility to optimize the PLL performance. Table 8 lists the bit settings vs. the nominal charge pump current. Table 8. PLL Charge Pump Current ICP (CFR3<21:19>) Charge Pump Current, ICP (μA) 000 212 001 237 010 262 011 287 100 312 101 337 110 363 111 387 EXTERNAL PLL LOOP FILTER COMPONENTS The PLL_LOOP_FILTER pin provides a connection interface to attach the external loop filter components. The ability to use custom loop filter components gives the user more flexibility to optimize the PLL performance. The PLL and external loop filter components are shown in Figure 52. PFD CP PLL_LOOP_FILTER VCO ÷N PLL OUT PLL IN AVDD REFCLK PLL 2 R1 C1 C2 Figure 52. REFCLK PLL External Loop Filter In the prevailing literature, this configuration yields a third- order, Type II PLL. To calculate the loop filter component values, begin with the feedback divider value (N), the gain of the phase detector (KD), and the gain of the VCO (KV) based on the programmed VCO SEL bit settings (see Table 1 for KV). The loop filter component values depend on the desired open-loop bandwidth (fOL) and phase margin (φ), as follows: φ K K Nf π R1 V D OL sin 1 1 (7) 2 2 tan OL V D f N K K C1 (8) φ φ f π N K K C2 OL V D cos sin 1 ) 2 ( 2 (9) where: KD equals the programmed value of ICP. KV is taken from Table 1. Ensure that proper units are used for the variables in Equation 7 through Equation 9. ICP must be in amps, not μA as appears in Table 8; KV must be in Hz/V, not MHz/V as listed in Table 1; the loop bandwidth (fOL) must be in Hz; the phase margin (φ) must be in radians. Furthermore, to limit the phase noise contribution of the internal VCO, the loop bandwidth must be 1 MHz or greater. For example, suppose the PLL is programmed such that ICP = 287 μA, KV = 850 MHz/V, and N = 25. If the desired loop bandwidth and phase margin are 1 MHz and 45°, respectively, the loop filter component values are R1 = 777.3 Ω, C1 = 494.3 pF, and C2 = 102.4 pF. PLL LOCK INDICATION When the PLL is in use, the PLL_LOCK pin provides an active high indication that the PLL has locked to the REFCLK input signal. When the PLL is bypassed, the PLL_LOCK pin defaults to Logic 0. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |