32 / 44 page ![]() AD8364 Data Sheet Rev. C | Page 32 of 44 Once slope and intercept have been calculated, an equation can be written that will allow calculation of the input power based on the output voltage of the detector. PIN (unknown) = (VOUT1(MEASURED)/Slope) + Intercept The log conformance error of the calculated power is given by Error (dB) = (VOUT(MEASURED) − VOUT(IDEAL))/Slope Figure 69 includes a plot of the error at 25°C, the temperature at which the log amp is calibrated. Note that the error is not zero. This is because the log amp does not perfectly follow the ideal VOUT vs. PIN equation, even within the operating region. The error at the calibration points (−43 dBm and −23 dBm in this case) will, however, be equal to zero by definition. Figure 69 also includes error plots for the output voltage at −40°C and +85 °C. These error plots are calculated using the slope and intercept at 25°C. This is consistent with calibration in a mass-production environment, where calibration at temperature is not practical. SELECTING CALIBRATION POINTS TO IMPROVE ACCURACY OVER A REDUCED RANGE In some applications, very high accuracy is required at one power level or over a reduced input range. For example, in a wireless transmitter, the accuracy of the high power amplifier (HPA) is most critical at or close to full power. Figure 70 shows the same measured data as Figure 69. Notice that accuracy is very high from −10 dBm to −25 dBm. At approximately −45 dBm, the error increases to about −0.3 dB because the calibration points have been changed to −15 dBm and −25 dBm. Calibration points must be chosen to suit the application at hand. In general, though, do not choose calibration points in the nonlinear portion of the log amp transfer function (above 0 dBm or below −50 dBm in this case). Figure 71 shows how calibration points can be adjusted to increase dynamic range, but at the expense of linearity. In this case, the calibration points for slope and intercept are set at −1 dBm and −50 dBm. These points are at the end of the device linear range. At 25°C, there is an error of 0 dB at the calibration points. Note also that the range over which the AD8364 maintains an error of <±0.4 dB is extended to 57 dB at 25°C. The disadvantage of this approach is that linearity suffers, especially at the top end of the input range. Another way of presenting the error function of a log amp detector is shown in Figure 72. In this case, the dB error at hot and cold temperatures is calculated with respect to the output voltage at ambient. This is a key difference in comparison to the previous plots, in which all errors have been calculated with respect to the ideal transfer function at ambient. When the alternative technique, the error at ambient becomes by definition equal to 0 (see Figure 72). This is valid if the device transfer function perfectly followed the ideal VOUT = Slope × (PIN − Intercept) equation. However, since an rms amp, in practice, never perfectly follows this equation (especially outside of the linear operating range), this plot tends to artificially improve linearity and extend the dynamic range, unless enough calibration points were taken to remove the error. This plot is a useful tool for estimating temperature drift at a particular power level with respect to the (nonideal) output voltage at ambient. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |