8 / 32 page ![]() DA6512.003 2 December, 2016 8 (32) OPERATING MODES MAS6512 has two capacitance measurement modes, a temperature measurement mode and a VDD level monitoring mode. In capacitance measurement mode the output is proportional to either capacitance difference (CS-CR) or to capacitance ratio (CS-CR)/CS. In temperature measurement mode the output is proportional to the absolute temperature. The VDD level monitoring mode allows measuring supply voltage which can be useful especially in battery operated systems. Measurement mode configuration and start of conversion is done by writing 8-bit configuration data to the Measurement control register (address E2HEX). See further details in the Measurement control register chapter. MAS6512 includes a 256-bit EEPROM memory for storing trim and calibration data on chip. Five bytes (40 bits) of EEPROM are reserved for trim values and programmable I2C device address but the remaining 27 bytes (216 bits) are free for storing sensor calibration and other data. The stored trim data consists of capacitive front-end offset and gain setting data that are automatically read from EEPROM memory in the beginning of each conversion (in normal operating mode). The programmable I2C device address is read from EEPROM memory only during power on reset or by manual reset using XCLR or the reset register. The stored calibration data should comprise of calibration and temperature compensation coefficients that can be used to calculate accurate sensor and temperature measurement results from the non-calibrated measurement readings. All calculations need to be done in an external micro controller unit (MCU) which controls the MAS6512. A calibrated MAS6512 sensor system should be operated as illustrated in figure 2. Connecting VDD triggers power-on-reset (POR) but to make sure the device is reset an additional reset should be given using the XCLR pin or writing any data on the reset register E0/60HEX via the serial bus. The calibration and compensation coefficients are necessary to be read to the MCU memory only once. From each pair of sensor and temperature measurement readings and using the calibration coefficients the accurate sensor and temperature values can then be calculated in the external MCU. All communication with MAS6512 is done using either the I2C bus or the SPI bus. Starting an A/D conversion, reading the conversion result and reading and writing data from and to the EEPROM memory are all accomplished via serial bus communication. In addition to the serial buses the digital interface includes also end-of-conversion (EOC) and master reset (XCLR) pins. See A/D Conversion in the Serial Data Interface (I2C Bus) Control chapter. Figure 2. Flow chart for a calibrated MAS6512 sensor system POWER UP / RESET Reset device by XCLR or by writing any data to the reset register E0/60HEX READ EEPROM CALIBRATION DATA MEASURE SENSOR MEASURE TEMPERATURE CALCULATE CALIBRATED TEMPERATURE CALCULATE TEMPERATURE COMPENSATED SENSOR VALUE |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |