Back Button E53-R Datasheet HTML 18Page - Omron Electronics LLC E53-R Datasheet HTML 19Page - Omron Electronics LLC E53-R Datasheet HTML 20Page - Omron Electronics LLC E53-R Datasheet HTML 21Page - Omron Electronics LLC E53-R Datasheet HTML 22Page - Omron Electronics LLC E53-R Datasheet HTML 23Page - Omron Electronics LLC E53-R Datasheet HTML 24Page - Omron Electronics LLC E53-R Datasheet HTML 25Page - Omron Electronics LLC E53-R Datasheet HTML 26Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 36 page
background image
22
Digital Controller
E5AK/E5EK
■ Alarm Mode Selectors
Alarm outputs are available if they are allocated as outputs. Factory setting is “2: Upper-limit alarm (deviation).”
Deviation Alarm
If the alarm mode selector is set to a number between 1 to 7, alarm
values are set to the width deviated from the set point as shown in
the following illustration.
Absolute Alarm
If the alarm mode selector is set to 8 or 9, alarm values are set to the
absolute value based on 0
°C/°F as shown in the following illustration.
When selecting a control method, refer to the following table for cor-
rect parameter setting.
Switch
setting
Alarm operation
Alarm output
When X is positive
When X is negative
1
Upper- and lower-limit alarm (deviation)
Always ON
2
Upper-limit alarm (deviation)
3
Lower-limit alarm (deviation)
4
Upper- and lower-limit range alarm (deviation)
Always OFF
5
Upper- and lower-limit alarm with standby se-
quence (deviation)
Always OFF
6
Upper-limit alarm with standby sequence (devia-
tion)
7
Lower-limit alarm with standby sequence (devia-
tion)
8
Absolute-value upper-limit alarm
9
Absolute-value lower-limit alarm
10
Absolute-value upper-limit alarm with standby se-
quence
11
Absolute-value lower-limit alarm with standby se-
quence
XX
ON
OFF
SP
X
SP
ON
OFF
X
SP
ON
OFF
X
SP
ON
OFF
X
SP
ON
OFF
XX
SP
ON
OFF
XX
SP
ON
OFF
X
SP
ON
OFF
X
SP
ON
OFF
X
SP
ON
OFF
X
SP
ON
OFF
X
0
ON
OFF
0
X
ON
OFF
X
0
ON
OFF
0
X
ON
OFF
X
0
ON
OFF
0
X
ON
OFF
X
0
ON
OFF
0
X
ON
OFF
10
°C/°F
110
°C/°F
Alarm value
Set point (SP)
100
°C/°F
0
°C/°F
110
°C/°F
110
°C/°F
Alarm value
Control
method
Control output
1 assignment
Control output
2 assignment
Operation
Heat
Control output
(heat)
---
Reverse
Cool
Control output
(heat)
---
Direct
Heat/Cool
Control output
(heat)
Control output
(cool)
Reverse



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com