| 数据搜索系统,热门电子元器件搜索 |
|
E53-R 数据表(PDF) 31 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E53-R 数据表(HTML) 31 Page - Omron Electronics LLC |
|
31 / 36 page ![]() Digital Controller E5AK/E5EK 31 ■ Fuzzy Self-tuning Fuzzy self-tuning is a function that enables the E5AK/E5EK to calcu- late the most suitable PID constants for the controlled object. Features • The E5AK/E5EK determines by itself when to perform fuzzy self- tuning. Fuzzy Self-tuning Function The fuzzy self-tuning function has three modes. In SRT (step response tuning) mode, the PID constants are tuned using a step response method at the time the set point is changed. In DT (disturbance tuning) mode, the PID constants are amended so that the controlled temperature will be within the target range set in advance when there is external disturbance. In HT (hunting tuning) mode, when hunting occurs, the PID con- stants are amended to suppress the hunting. Note: Be sure to turn on the power supply to the load either before or simultaneously with the start of Temperature Controller opera- tion. Dead time will be measured from the time the Temperature Controller starts operating. If a load such as a heater is turned on after the Temperature Controller is turned on, dead time longer than the actual value will be measured and inappropri- ate PID constants will be obtained. If an extremely large amount of dead time is measured, the control amount will be set to 0% for a short period of time before being returned to 100%, and the constants will then be retuned. Retuning is per- formed only for large amounts of dead time, so be sure to follow the precaution given above when starting operation. Startup Conditions of SRT SRT will start if the following conditions are satisfied simultaneously when the E5AK/E5EK is turned on or the set point is changed. Note: The last SRT-executed set point is set to 0 before shipping and when changing from advanced PID control to advanced PID control with fuzzy self-tuning. PID Constant Refreshing Conditions If the step control amount is applied before the maximum tempera- ture slope (R) is obtained, SRT will not renew any PID constant. If the proportional band obtained from the R and L values that were mea- sured before the imposition had been completed is larger than the present proportional band, the PID constants will be renewed because the measured value is in the direction towards the suitable proportional band value, and the set point at that time will be the SRT-executed set point. Stable Temperature Status If the temperature is within the stable range for a certain time, it is deemed that the temperature is stable. This time is called stability judgement time. Like PID constants, stability judgement time is adjusted with fuzzy self-tuning according to the characteristics of the object to be controlled. Fuzzy self-tuning will not be activated if the temperature is stable because the Temperature Controller deems that temperature control is smooth. Balanced Status If the process value is within the stable range for 60 s when there is no output, it is deemed that the temperature is balanced. Startup Conditions of DT 1. DT will start if the temperature that has been stable varies due to external disturbance and the deflection of the temperature exceeds the stable range, and then the temperature becomes stable, provided that the number of maximum temperature values is less than four. 2. DT will start if the set point is changed under the condition that SRT does not start and the temperature becomes stable, pro- vided that the number of maximum temperature values is less than four. If there are four or more maximum temperature values, HT will start. At the time the E5AK/E5EK starts operating At the time set point is changed 1. The set point at the time the E5AK/E5EK starts operating is different from the set point used at the time SRT was last executed (see note). 2. The process value at the time the E5AK/E5EK starts operat- ing is smaller than the set point in reverse operation and larger than the set point in normal operation. 1. The new set point is different from the set point used at the time SRT was last executed (see note). 2. The process value is in stable condition before the set point is changed. 3. A larger set point value is set in reverse operation and a smaller set point is set in nor- mal operation. Temperature Slope (R) Stable range Time SP Shorter than the stability judgement time Stability judgement time Stable Stable Set point Stable range Stable range (Set to 15.0 °C before shipping) SP Temperature Extreme value 2 Set point change Time Extreme value 1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |