| 数据搜索系统,热门电子元器件搜索 |
|
E53-R 数据表(PDF) 3 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E53-R 数据表(HTML) 3 Page - Omron Electronics LLC |
|
3 / 36 page ![]() Digital Controller E5AK/E5EK 3 ■ Accessories (Order Separately) Note: No CT is required unless the heater burnout alarm function is used. Specifications ■ Ratings Note: 1. All control outputs are insulated from the input circuit. 2. Fuzzy self-tuning is available when using the Digital Controller in standard control operation with temperature input. ■ Input Ranges Platinum Resistance Thermometer Name Model Hole diameter Current Transformer E54-CT1 5.8 mm E54-CT3 12.0 mm Name Model Connectable models Terminal Cover E53-COV0809 E5AK E53-COV08 E5EK Item AC100-240V type AC/DC24V type Supply voltage AC100 to 240V, 50/60 Hz AC/DC24V, 50/60 Hz Power consumption E5AK: 16 VA E5EK: 15 VA 12 VA, 8 W Operating voltage range 85% to 110% of rated supply voltage Input Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII Platinum resistance thermometer: JPt100, Pt100 Current input: 4 to 20 mA, 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V Input impedance Current input: 150 Ω; Voltage input: 1 MΩ min. Control output Standard Model According to Output Unit (see “Output Unit Ratings and Characteristics”) Position-proportional Model 2 Relay outputs: SPST-NO, 1 A at 250 VAC (including inrush current) (see note 1) Auxiliary output SPST-NO, 3 A at 250 VAC (resistive load) Control method (see note 2) ON/OFF or 2-PID control (with auto-tuning) Setting method Digital setting using front panel keys Indication method 7-segment digital display and LEDs Potentiometer 100 Ω to 2.5 kΩ Event input Contact input: ON: 1 k Ω max., OFF: 100 kΩ min. No-contact input: ON: residual voltage: 1.5 V max., OFF: leakage current: 0.1 mA max. Transfer output 4 to 20 mA, permissible load impedance: 600 Ω max., resolution: approx. 2,600 Remote SP input Current input: 4 to 20 mA (Input impedance: 150 Ω) Current Transformer input Connect an exclusive Current Transformer (E54-CT1 or E54-CT3) Other functions Standard Manual output, heating/cooling control, SP limiter, loop burnout alarm, SP ramp, MV limiter, MV change rate limiter, input digital filter, input shift, run/stop, protect functions Option Multiple SP, run/stop selection, transfer output functions Degree of protection Conforms to IEC IP66 and NEMA4 (Indoor use) Input (switch selectable) JPt100 Pt100 Range °C −199.9 to 650.0 −199.9 to 650.0 °F −199.9 to 999.9 −199.9 to 999.9 Setting 01 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |