24 / 200 page ![]() Table 21. MB_LEN_Dyn Bit Name Function Factory Value b7-b0 MB_LEN Size in byte, minus 1 byte, of message contained in FTM mailbox (automatically set by ST25DVxxx) 0h Note: Refer to Table 12. Dynamic registers memory map for the MB_LEN_Dyn register. 5.1.2 Fast transfer mode usage ST25DV acts as mailbox between RF (reader, smartphone, ...) and an I2C host (microcontroller...). Each interface can send a message containing up to 256 bytes of data to the other interface through that mailbox. To send data from RF reader to I2C host, fast transfer mode must be enabled, the mailbox must be free, VCC power must be present, and the RF user must first writes the message containing data in the mailbox. I2C host is then informed (by interruption on GPO output or polling on MB_CTRL_Dyn register) that a message from RF is present in the mailbox. Once the complete message has been read by I2C, mailbox is considered free again and is available for receiving a new message (data is not cleared). The RF user is informed that the message has been read by the I2C host by polling on MB_CTRL_Dyn register. Figure 9. RF to I2C fast transfer mode operation I2C host ST25DV Fast Transfer Mode mailbox (256 Bytes) Dynamic registers MB_LEN_Dyn MB_CRTL_Dyn Static registers MB_MODE MB_WDG ISO/IEC 15693 reader I2C GPO/RF_PUT_MSG RF message 1Mb/s 26.5kb/s To send data from the I2C host to the RF reader, fast transfer mode must be enabled, the mailbox must be free, VCC power must be present, and the I2C host must first write the message containing data in the mailbox. The RF user must poll on MB_CTRL_Dyn register to check for the presence of a message from I2C in the mailbox. Once the complete message has been read by RF user, mailbox is considered free again and is available for receiving a new message (data is not cleared). The I2C host is informed that message has been read by RF user through a GPO interruption or by polling on the MB_CTRL_Dyn register. ST25DV04K ST25DV16K ST25DV64K Fast transfer mode (FTM) DS10925 - Rev 9 page 24/200 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |