13 / 135 page ![]() 3.2.2 Voltage regulator: V2 The SPSB081 embeds one 5 V or 3V3 (configurable by V2_RAIL bit in CR2) low dropout tracking regulator designed to provide an output voltage that closely tracks (±20 mV) the V1 reference input while delivering on the V2 output pin up to 100 mA. The voltage regulator V2 can be configured by means of the V2_TKR bit in CR2 as a linear independent LDO (V2_TKR=0, default) or as a tracker of the V1 voltage regulator (V2_TKR=1). The V2 can be configured as tracker of the V1 only at the same voltage output level 5 V for SPSB0815 and SPSB081C5 (Conf #4 in Table 6) and 3.3 V for the SPSB0813 and SPSB081C3 (Conf #1 in Table 6). The tracking regulator is protected against: • overload • overtemperature • short-circuit (short to ground and battery supply voltage) • reverse biasing 3.2.3 Voltage regulator failure The V1 and V2 regulators output voltages are monitored. In case of a drop below the V1, V2 fail thresholds (V1,2 < V1,2fail, for t > tV1,2fail), the failure bits V1FAIL, V2FAIL (SR 2) are latched. The fail bits can be cleared by a dedicated SPI command. 3.2.4 Short to ground detection At turn-on of the V1 and V2 regulators, a short to GND condition is detected by monitoring the regulator output voltage. If V1 or V2 is below the V1fail,(V2fail) thresholds for t>tv1short (t>tV2short) after turn-on, the SPSB081 will identify a short-circuit condition at the related regulator output and the regulator will be switched off. In case of V1 short to GND the device enters VBAT_standby mode automatically. Bits FORCED_SLEEP_TSD2/V1SC (SR1) and V1FAIL (SR2) are set. In case of a V2 short to GND failure the V2SC (SR2) and V2FAIL (SR2) bits are set. Once the output voltage of the corresponding regulator exceeds the V1fail (V2fail) thresholds the short-to-ground detection is disabled. In case of a short-to-ground condition, the regulator is switched off due to thermal shutdown. SPSB081 Voltage regulators DS14048 - Rev 1 page 13/135 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |