Back Button VL6180 Datasheet HTML 24Page - STMicroelectronics VL6180 Datasheet HTML 25Page - STMicroelectronics VL6180 Datasheet HTML 26Page - STMicroelectronics VL6180 Datasheet HTML 27Page - STMicroelectronics VL6180 Datasheet HTML 28Page - STMicroelectronics VL6180 Datasheet HTML 29Page - STMicroelectronics VL6180 Datasheet HTML 30Page - STMicroelectronics VL6180 Datasheet HTML 31Page - STMicroelectronics VL6180 Datasheet HTML 32Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 28 / 73 page
background image
Functional description
VL6180
28/73
DocID024986 Rev 14
2.15
Other system considerations
This section describes part-to-part range offset and system cross-talk. In addition, a
procedure for cross-talk calibration is given.
2.15.1
Part-to-part range offset
The VL6180 is factory calibrated to produce an absolute linear range output as shown in
Figure 18. The part-to-part range offset is calibrated during manufacture and stored in NVM.
Use VL6180x_GetOffsetCalibrationData() to read offset from NVM (after
VL6180x_InitData()). The API always returns the range with the part-to-part offset already
applied.
Figure 18. Part-to-part range offset
2.15.2
Cross-talk
Cross-talk is defined as the signal return from the cover glass. The magnitude of the cross-
talk depends on the type of glass, air gap and filter material. Cross-talk results in a range
error (see Figure 19) which is proportional to the ratio of the cross-talk to the signal return
from the target. The true range is recovered by applying automatic cross-talk compensation.
Figure 19. Cross-talk compensation
Cross-talk compensation is enabled by using VL6180x_SetXTalkCompensationRate(). A
cross-talk calibration procedure is described in Section 2.15.4.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com