| 数据搜索系统,热门电子元器件搜索 |
|
HVLED101 数据表(PDF) 14 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
HVLED101 数据表(HTML) 14 Page - STMicroelectronics |
|
14 / 36 page ![]() Once the protection set-up is fetched, the following pins are pulled up: FB, VL, FAULT and OPTO. When the voltage on the FAULT pin is higher than VFLT-ON threshold, the HVSU recharges the VCC capacitor and the switching activity starts. The first switching cycles activate the next operating phase: the ramp-up phase. 6.2.2 Ramp-up phase This operating mode is intended to ensure a safe increase of the output voltage. This goal is achieved transferring an almost constant power to the output by fixing the minimum current sense threshold at VCS-RU and driving the external power MOSFET at constant operating frequency FSW-RU, with the maximum duty cycle fixed at 50%. The THD optimizer unit is forced to operate with a duty cycle equal to 1 (see relevant section for further details). Figure 6. Ramp-up waveforms Max duty fixed by CK falling edge VGD VCS-RU VCS FSW-RU When both output voltages (read by ZCD sample and hold block) are higher than VUVP threshold and OPTO pin is pulled up for at least TOPTO-TRIG, the IC enters active mode. If the ramp-up exit condition is not satisfied within TCF, the IC shuts down, and automatic restart is attempted after TART. During this phase the internal PSR error amplifier is always on as well as the FAULT pin pull-up current. 6.2.3 Active mode During active mode, the IC provides the GD signal to drive the external power switch according to application signals. All the parameters are set at their operating range performance and protections are ready to manage undesired events. The power consumption of the IC in this phase depends on the switching frequency and the characteristics of the adopted switch. The OPTO disable feature activates a deep low consumption mode, while the FAULT disable mean activates a standard low consumption mode. The input OVP is active (in CFG 1, 3 and 5) as well as the brownout and output undervoltage protections. 6.2.4 Low consumption mode In this state, the IC stops switching activity and turns off the major part of internal structures in order to reduce VCC consumption down to ICC-LC. In this operating mode, the high-voltage startup logic is active to maintain the VCC pin above VCC-OFF (low level) if necessary. This state is invoked when the following conditions are met: • overcurrent protection. • FAULT pin protection. • the inactive phase of brownout level protection is running. • input overvoltage protection senses an excessive input voltage at pin HVSU. HVLED101 Operating modes DS14143 - Rev 2 page 14/36 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |