31 / 46 page ![]() P9221-R3 Datasheet © 2017 Integrated Device Technology, Inc. 31 October 20, 2017 Address and Bit Register or Bit Field Name R/W Default Function and Description 0034HEX [1] VRECT_OV_ Status R 0BIN “1” indicates the rectifier voltage exceeds 20V for VOUT=12V. In this case, the P9221-R3 sends an End Power Transfer (EPT) packet to the transmitter. 0034HEX [0] Current_Limit_Status R 0BIN “1” indicates the current limit has been exceeded. In this case, the P9221-R3 sends an End Power Transfer (EPT) packet to the transmitter. 0035HEX [7:0] Reserved R 00HEX Table 15. Interrupt Status Registers Address and Bit Register or Bit Field Name R/W Default Function and Description 0036HEX [7] INT_Vout_Status R 0BIN “0” indicates the output voltage has not changed. “1” indicates the output voltage changed. 0036HEX [6] Reserved R 0BIN 0036HEX [5] Reserved R 0BIN 0036HEX [4] User_Data_Received_status R 0BIN “1” indicates that the P9221-R3 has received data from the P9242-R3. This bit must be reset after the application processor reads the user data. 0036HEX [3] Reserved R 0BIN 0036HEX [2] INT_OVER_TEMP_Status R 0BIN “1” indicates an over-temperature condition exists. 0036HEX [1] INT_VRECT_OV_Status R 0BIN “1” indicates a rectifier over-voltage condition exists. 0036HEX [0] INT_OC_Limit_Status R 0 “1” indicates the current limit has been exceeded. 0037HEX [7:0] Reserved R 00HEX Note: If any bit in the Interrupt Status register 0036HEX is “1” and the corresponding bit in the Interrupt Enable register 38HEX is set to “1,” the INT pin will be pulled down indicating an interrupt event has occurred. Table 16. Interrupt Enable Registers Address and Bit Register or Bit Field Name R/W Default Function and Description 0038HEX [7] Vout_Status_INT_EN RW 0BIN “0” disables the INT_Vout_Status interrupt. "1" enables the interrupt. 0038HEX [6] Reserved R 0BIN 0038HEX [5] Reserved R 0BIN 0038HEX [4] User_Data_Received_EN R 1BIN “0” disables the User_Data_Received interrupt. "1" enables the interrupt. 0038HEX [3] Reserved R 1BIN 0038HEX [2] OVER_TEMP_INT_EN R 1BIN “0” disables the INT_OVER_TEMP interrupt. "1" enables the interrupt. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |