| 数据搜索系统,热门电子元器件搜索 |
|
AD9511-VCO/PCB 数据表(PDF) 31 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9511-VCO/PCB 数据表(HTML) 31 Page - Analog Devices |
|
31 / 60 page ![]() AD9511 Rev. A | Page 31 of 60 Phase Frequency Detector (PFD) and Charge Pump The PFD takes inputs from the R counter and the N counter (N = BP + A) and produces an output proportional to the phase and frequency difference between them. Figure 36 is a simplified schematic. The PFD includes a programmable delay element that controls the width of the antibacklash pulse. This pulse ensures that there is no dead zone in the PFD transfer function and minimizes phase noise and reference spurs. Two bits in Register 0Dh <1:0> control the width of the pulse. D1 Q1 U1 CLR1 R DIVIDER HI UP D2 Q2 U2 CLR2 N DIVIDER HI DOWN CP CHARGE PUMP VP GND U3 PROGRAMMABLE DELAY ANTIBACKLASH PULSE WIDTH Figure 36. PFD Simplified Schematic and Timing (In Lock) Antibacklash Pulse The PLL features a programmable antibacklash pulse width that is set by the value in Register 0Dh<1:0>. The default antibacklash pulse width is 1.3 ns (0Dh<1:0> = 00b) and normally should not need to be changed. The antibacklash pulse eliminates the dead zone around the phase-locked condition and thereby reduces the potential for certain spurs that could be impressed on the VCO signal. STATUS Pin The output multiplexer on the AD9511 allows access to various signals and internal points on the chip at the STATUS pin. Figure 37 shows a block diagram of the STATUS pin section. The function of the STATUS pin is controlled by Register 08h<5:2>. PLL Digital Lock Detect The STATUS pin can display two types of PLL lock detect: digital (DLD) and analog (ALD). Whenever digital lock detect is desired, the STATUS pin provides a CMOS level signal, which can be active high or active low. The digital lock detect has one of two time windows, as selected by Register 0Dh<5>. The default (ODh<5> = 0b) requires the signal edges on the inputs to the PFD to be coincident within 9.5 ns to set the DLD true, which then must separate by at least 15 ns to give DLD = false. The other setting (ODh<5> = 1b) makes these coincidence times 3.5 ns for DLD = true and 7 ns for DLD = false. The DLD may be disabled by writing 1 to Register 0Dh<6>. If the signal at REFIN goes away while DLD is true, the DLD will not necessarily indicate loss-of-lock. See the Loss of Reference section for more information. OFF (LOW) (DEFAULT) DIGITAL LOCK DETECT (ACTIVE HIGH) N DIVIDER OUTPUT DIGITAL LOCK DETECT (ACTIVE LOW) R DIVIDER OUTPUT ANALOG LOCK DETECT (N-CHANNEL OPEN DRAIN) A COUNTER OUTPUT PRESCALER OUTPUT (NCLK) PFD UP PULSE PFD DOWN PULSE LOSS OF REFERENCE (ACTIVE HIGH) TRI-STATE ANALOG LOCK DETECT (P-CHANNEL OPEN DRAIN) LOSS OF REFERENCE OR LOCK DETECT (ACTIVE HIGH) LOSS OF REFERENCE OR LOCK DETECT (ACTIVE LOW) LOSS OF REFERENCE (ACTIVE LOW) PLL MUX CONTROL 08h <5:2> SYNC DETECT ENABLE 58h <0> SYNC DETECT VS GND STATUS PIN Figure 37. STATUS Pin Circuit CLK1 Clock Input |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |