| 数据搜索系统,热门电子元器件搜索 |
|
ST25R200 数据表(PDF) 68 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST25R200 数据表(HTML) 68 Page - STMicroelectronics |
|
68 / 88 page ![]() 5.15.8 Calibrate WU measurement The command calibrates the WU measurement. The command is triggered manually and may also be automatically executed during WU mode (depending on skip_cal and skip_recal configuration bits). When executed from PD mode it first triggers the transition to RD mode, waits for the oscillator to become stable, enables the field, and then performs the measurement. In RD mode, it enables the field and then performs the measurement itself. Calibration result available in the I/Q channel WU display calibration registers. 5.15.9 Clear WU calibration The command clears the WU calibration to its default value. Calibration result is available in the I/Q channel WU display calibration registers. 5.15.10 I/Q measurement and sense RF These commands allow the user to measure the I and Q components of the RFI signal, whether it is an external or self-emitted field. The measurements are similar to the WU measurement but they can only be triggered once in RD mode and the state of the transmitter is kept. Depending on tx_en it measures its own field, or check for the presence of an external one. Before executing the measurement, a clear WU calibration command shall be executed. The measurement result is available at: • I/Q measurement: i_adc<7:0> and q_adc<7:0> • Sense RF: rf_ind<6:0> as a combination of I and Q Note: Both measurements take into account the configured gain, and calibration configuration. In the absence of the self ‑emitted field, the external signal is not synchronous and may lead to uneven results. It may be used to check for the presence of an external field, but not to accurately assess its intensity. 5.15.11 Transparent mode This command sets the receiver and transmitter into the transparent mode. The device enters the transparent mode on the rising edge of the BSS signal of the SPI frame used to send the direct command. The transparent mode is maintained as long as the signal BSS is kept high, that is, the following SPI command sent from the host is automatically stopped the transparent mode. 5.15.12 Start GPT This command manually starts the general purpose timer. 5.15.13 Start WUT This command manually starts the wake-up timer. 5.15.14 Start MRT This command manually starts the mark receive timer. Along with MRT, Start MRT command starts the NRT in case nrt<15:0> ≠ 0. 5.15.15 Start NRT This command manually starts the no response timer. 5.15.16 Stop NRT This command manually stops the no response timer. ST25R200 Application information DS13658 - Rev 2 page 68/88 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |