| 数据搜索系统,热门电子元器件搜索 |
|
TNETE2101 数据表(PDF) 29 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETE2101 数据表(HTML) 29 Page - Texas Instruments |
|
29 / 39 page ![]() TNETE2101 10BASE-T/100BASE-TX/100BASE-FX LOW-POWER PHYSICAL-LAYER INTERFACE SPWS032D – JANUARY 1997 – REVISED MARCH 1999 29 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PHY status register – TXPHY_sts at 0x12 BIT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 BIT 0 MINT PHOK PLOK TPENERGY SYNCLOSS FEFI Reserved Figure 18. PHY Status Register Table 16. PHY Status-Register Bit Functions BIT FUNCTION NAME NO. FUNCTION MINT† 15 MII Interrupt. MINT indicates an MII-interrupt condition. The MII-interrupt request is activated and latched until this register is read. Writing to MINT has no effect. MINT is set to 1 when: – JABBER (register 0x0, bit 1) is set to 1. – LINK (register 0x0, bit 2) changes state or is different from either the last read value or the current state of the link. – RFAULT (register 0x1, bit 4) is set to 1. – AUTOCMPLT (register 0x1, bit 5) is set to 1. – PAGERX (register 0x6, bit 1) is set to 1. – FEFI (register 0x12, bit 10) is set to 1. – SYNCLOSS (register 0x12, bit 11) is set to 1. – PHOK (register 0x12, bit 14) is set to 1. Additional interrupt sources are active only when the MANCONF bit (register 0x11, bit 13) is set to 1. MINT is set to a 1 when: – TPENERGY (register 0x12, bit 12) is set to 1. – PLOK (register 0x12, bit 13) changes state. PHOK 14 Power high OK. When PHOK is set to 1, it indicates that the oscillator circuit connected to XTAL1 has begun to oscillate (and perform around 75 cycles). PHY-sourced clocks (MRCLK and MTCLK) are not valid until PHOK is asserted. The clocks can take up to 50 ms to become stable and the PHY requires the RESET bit to be set to make certain it is in a valid state. When PHOK is 0, the PHY is not in a fully operational state. PLOK 13 Polarity OK. PLOK set to a 1 (default) signifies that the 10BASE-T PHY is receiving valid (noninverted) link pulses. PLOK always is set to a 1 when MANCONF is set to a 0, since the PHY automatically corrects polarity. If MANCONF is set to a 1 for manual polarity configuration, PLOK is cleared to a 0 if a sequence of seven consecutive inverted link pulses is detected. PLOK can be set to a 1 again only if the SWAPOL bit is toggled and then 1 noninverted link pulse is received. If MANCONF is a 1 and then cleared to a 0 when PLOK is still a 0, PLOK is not set to a 1 until SWAPOL is toggled. This reenables the autopolarity detection and PLOK remains a 1. 10BASE-T polarity is determined strictly from link pulses and not from received data or TP idles. TPENERGY 12 Twisted-pair energy detect. When TPENERGY is set to 1, it indicates that the PHY is receiving impulses on ARCVP/ARCVN. SYNCLOSS 11 100BASE-TX receive descrambler synchronization loss. The 100BASE-TX descrambler expects to receive at least 12 consecutive IDLE symbols every 722 µs. If these are not seen, then SYNCLOSS is set to 1, and the descrambler attempts to resynchronize itself to the incoming scrambled data stream. The value of SYNCLOSS is latched high until this register is read. FEFI 10 Far-end fault indication. When enabled via the FEFEN bit in TXPHY_ctl, this bit is set to 1 if the FEFI signaling sequence is being transmitted by the link partner. The value of FEFI is latched (held) high until this register is read. Reserved 9–0 Reserved. Read and write as 0. † Useful for switching applications (TI patented) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |