| 数据搜索系统,热门电子元器件搜索 |
|
ADE7569 数据表(PDF) 87 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7569 数据表(HTML) 87 Page - Analog Devices |
|
87 / 144 page ![]() ADE7566/ADE7569/ADE7166/ADE7169 Rev. A | Page 87 of 144 SUBB A, Source This instruction subtracts the source byte and the carry (borrow) flag from the accumulator. It references the carry (borrow) status flag. Affected Status Flags C Set if there is a borrow needed for Bit 7. Cleared otherwise. Used to indicate an overflow if the operands are unsigned. OV Set if there is a borrow needed for Bit 6 or Bit 7, but not for both. Used to indicate an overflow for signed subtraction. This flag is set if a negative number subtracted from a positive yields a negative result or if a positive number subtracted from a negative number yields a positive result. AC Set if a borrow is needed for Bit 3. Cleared otherwise. MUL AB This instruction multiplies the accumulator by the B register. This operation is unsigned. The lower byte of the 16-bit product is stored in the accumulator and the higher byte is left in the B register. No status flags are referenced by the instruction. Affected Status Flags C Cleared OV Set if the result is greater than 255. Cleared otherwise. DIV AB This instruction divides the accumulator by the B register. This operation is unsigned. The integer part of the quotient is stored in the accumulator and the remainder goes into the B register. No status flags are referenced by the instruction. Affected Status Flags C Cleared OV Cleared unless the B register is equal to 0, in which case the results of the division are undefined and the OV flag is set. DA A This instruction adjusts the accumulator to hold two 4-bit digits after the addition of two binary coded decimals (BCDs) with the ADD or ADDC instructions. If the AC bit is set or if the value of Bit 0 to Bit 3 exceeds nine, 0x06 is added to the accumulator to correct the lower four bits. If the carry bit is set when the instruction begins, or if 0x06 is added to the accumulator in the first step, 0x60 is added to the accumulator to correct the higher four bits. The carry and AC status flags are referenced by this instruction. Affected Status Flag C Set if the result is greater than 0x99. Cleared otherwise. RRC A This instruction rotates the accumulator to the right through the carry flag. The old LSB of the accumulator becomes the new carry flag, and the old carry flag is loaded into the new MSB of the accumulator. The carry status flag is referenced by this instruction. Affected Status Flag C Equal to the state of ACC.0 before execution of the instruction. RLC A This instruction rotates the accumulator to the left through the carry flag. The old MSB of the accumulator becomes the new carry flag, and the old carry flag is loaded into the new LSB of the accumulator. The carry status flag is referenced by this instruction. Affected Status Flag C Equal to the state of ACC.7 before execution of the instruction. CJNE Destination, Source, Relative Jump This instruction compares the source value to the destination value and branches to the location set by the relative jump if they are not equal. If the values are equal, program execution continues with the instruction after the CJNE instruction. No status flags are referenced by this instruction. Affected Status Flag C Set if the source value is greater than the destination value. Cleared otherwise. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |