| 数据搜索系统,热门电子元器件搜索 |
|
ADE7569 数据表(PDF) 31 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7569 数据表(HTML) 31 Page - Analog Devices |
|
31 / 144 page ![]() ADE7566/ADE7569/ADE7166/ADE7169 Rev. A | Page 31 of 144 USING THE POWER SUPPLY FEATURES In an energy meter application, the 3.3 V power supply (VDD) is typically generated from the ac line voltage and regulated to 3.3 V by a voltage regulator IC. The preregulated dc voltage, typically 5 V to 12 V, can be connected to VDCIN through a resistor divider. A 3.6 V battery can be connected to VBAT. Figure 33 shows how the ADE7566/ADE7569/ADE7166/ ADE7169 power supply inputs are set up in this application. Figure 34 shows the sequence of events that occurs if the main power supply generated by the PSU starts to fail in the power meter application shown in Figure 33. The SAG detection can provide the earliest warning of a potential problem on VDD. When a SAG event occurs, user code can be configured to backup data and prepare for battery switchover if desired. The relative spacing of these interrupts depends on the design of the power supply. Figure 35 shows the sequence of events that occurs if the main power supply starts to fail in the power meter application shown in Figure 33, with battery switchover on low VDCIN or low VDD enabled. Finally, the transition between VDD and VBAT and the different power supply modes (see the Operating Modes section) are represented in Figure 36 and Figure 37. VOLTAGE SUPERVISORY POWER SUPPLY MANAGEMENT IPSMF SFR (ADDR. 0xF8) VSW VBAT VSWOUT VDD 58 61 60 VOLTAGE SUPERVISORY 64 VDCIN 3.3V REGULATOR 5V TO 12V DC PSU 50 SAG DETECTION 49 45 BCTRL VP VN (240V, 220V, 110V TYPICAL) AC INPUT Figure 33. Power Supply Management for Energy Meter Application t1 t2 VDD VDCIN VP – VN 2.75V 1.2V SAG LEVEL TRIP POINT SAGCYC = 1 SAG EVENT (FSAG = 1) VDCIN EVENT (FVDCIN = 1) IF SWITCHOVER ON LOW VDD IS ENABLED, AUTOMATIC BATTERY SWITCHOVER VSWOUT CONNECTED TO VBAT BSO EVENT (FBSO = 1) Figure 34. Power Supply Management Interrupts and Battery Switchover with Only VDD Enabled for Battery Switchover |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |