139 / 173 page ![]() ST7LITE3xF2 139/173 13.3.2 Operating Conditions with Low Voltage Detector (LVD) TA = -40 to 125°C, unless otherwise specified Notes: 1. Not tested in production. The VDD rise time rate condition is needed to insure a correct device power-on and LVD reset. When the VDD slope is outside these values, the LVD may not ensure a proper reset of the MCU. 2. Use of LVD with capacitive power supply: with this type of power supply, if power cuts occur in the application, it is rec- ommended to pull VDD down to 0V to ensure optimum restart conditions. Refer to circuit example in Figure 98 on page 154. 13.3.3 Auxiliary Voltage Detector (AVD) Thresholds, TA = -40 to 125°C, unless otherwise specified 13.3.4 Internal RC Oscillator and PLL The ST7 internal clock can be supplied by an internal RC oscillator and PLL (selectable by option byte). Symbol Parameter Conditions Min Typ Max Unit VIT+(LVD) Reset release threshold (VDD rise) High Threshold, TA=-40 to +85°C High Threshold, TA=-40 to +125°C Med. Threshold Low Threshold 3.60 3.60 3.05 2.45 4.15 4.15 3.45 2.85 4.60 4.65 3.90 3.20 V VIT-(LVD) Reset generation threshold (VDD fall) High Threshold Med. Threshold Low Threshold 3.40 2.90 2.40 3.95 3.30 2.70 4.35 3.70 3.00 Vhys LVD voltage threshold hysteresis VIT+(LVD)-VIT-(LVD) 200 mV VtPOR VDD rise time rate 1)2) 20 100000 µs/V tg(VDD) Filtered glitch delay on VDD Not detected by the LVD 150 ns IDD(LVD) LVD/AVD current consumption 220 µA Symbol Parameter Conditions Min Typ Max Unit VIT+(AVD) 1=>0 AVDF flag toggle threshold (VDD rise) High Threshold, TA=-40 to +85°C High Threshold, TA=-40 to +125°C Med. Threshold Low Threshold 3.90 3.90 3.45 2.90 4.45 4.45 3.90 3.30 4.85 4.90 4.30 3.65 V VIT-(AVD) 0=>1 AVDF flag toggle threshold (VDD fall) High Threshold, TA=-40 to +85°C High Threshold, TA=-40 to +125°C Med. Threshold Low Threshold 3.85 3.80 3.35 2.75 4.40 4.40 3.85 3.15 4.80 4.80 4.20 3.50 Vhys AVD voltage threshold hystere- sis VIT+(AVD)-VIT-(AVD) 150 mV ∆V IT- Voltage drop between AVD flag set and LVD reset activation VDD fall 0.45 V Symbol Parameter Conditions Min Typ Max Unit VDD(RC) Internal RC Oscillator operating voltage Refer to operating range of VDD with TA, section 13.3.1 on page 133 2.7 5.5 V VDD(x4PLL) x4 PLL operating voltage 2.7 3.6 VDD(x8PLL) x8 PLL operating voltage 3.3 5.5 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |