| 数据搜索系统,热门电子元器件搜索 |
|
HT83F40P 数据表(PDF) 41 Page - Holtek Semiconductor Inc |
|
|
|||||||||||||||||||||||||||||
HT83F40P 数据表(HTML) 41 Page - Holtek Semiconductor Inc |
|
41 / 61 page ![]() HT83FXX Rev. 1.00 41 May 12, 2009 Low Drop Output - LDO All device include a fully integrated LDO regulator which can be used to provide a fixed voltage for user applica- tions. The integrated LDO is a simple three terminal de- vice with an external input pin, LDO_IN, external output pin, LDO_OUT, and a ground pin connected to the de- vice VSS pin. Implemented in CMOS technology, it can deliver a 100mA output current and allow an input volt- age as high as 24V. It will supply a fixed output voltage level of 3.3V. Using CMOS technology ensures that the regulator has a low dropout voltage and a low quiescent current. Low Voltage Detector - LVD The Low Voltage Detector internal function provides a means for the user to monitor when the power supply voltage falls below a certain fixed level as specified in the DC characteristics. Operation The Low Voltage Detector must first be enabled using a configuration option. The LVD control bit is bit 2 of the PWMCR regsiter and is known as LVDF. Under normal operation, and when the power supply voltage is above the specified VLVD value in the DC characteristic section, the LVDF bit will remain at a zero value. If the power supply voltage should fall be- low this VLVD value then the LVDF bit will change to a high value indicating a low voltage condition. Note that the LVDF bit is a read-only bit. By polling the LVDF bit in the PWMCR register, the application program can there- fore determine the presence of a low voltage condition. Watchdog Timer The Watchdog Timer is provided to prevent program malfunctions or sequences from jumping to unknown lo- cations, due to certain uncontrollable external events such as electrical noise. It operates by providing a de- vice reset when the WDT counter overflows. The WDT clock is supplied by one of two sources selected by con- figuration option: its own self-contained dedicated inter- nal WDT oscillator, or the instruction clock which is the system clock divided by 4. Note that if the WDT configu- ration option has been disabled, then any instruction re- lating to its operation will result in no operation. The internal WDT oscillator has an approximate period of 65 ms at a supply voltage of 5V. If selected, it is first di- vided by 256 via an 8-stage counter to give a nominal period of 17ms. Note that this period can vary with VDD, temperature and process variations. For longer WDT time-out periods the WDT prescaler can be utilized. By writing the required value to bits 0, 1 and 2 of the WDTS register, known as WS0, WS1 and WS2, longer time-out periods can be achieved. With WS0, WS1 and WS2 all equal to 1, the division ratio is 1:128 which gives a maxi- mum time-out period of about 2.1s. A configuration option can select the instruction clock, which is the system clock divided by 4, as the WDT clock source instead of the internal WDT oscillator. If the in- struction clock is used as the clock source, it must be noted that when the system enters the Power Down Mode, as the system clock is stopped, then the WDT clock source will also be stopped. Therefore the WDT will lose its protecting purposes. In such cases the sys- tem cannot be restarted by the WDT and can only be re- started using external signals. For systems that operate in noisy environments, using the internal WDT oscillator is therefore the recommended choice. Under normal program operation, a WDT time-out will initialise a device reset and set the status bit TO. How- ever, if the system is in the Power Down Mode, when a WDT time-out occurs, only the Program Counter and Stack Pointer will be reset. Three methods can be adopted to clear the contents of the WDT and the WDT prescaler. The first is an external hardware reset, which means a low level on the RES pin, the second is using the watchdog software instructions and the third is via a ²HALT² instruction. There are two methods of using software instructions to clear the Watchdog Timer, one of which must be chosen by configuration option. The first option is to use the sin- gle ²CLR WDT² instruction while the second is to use the two commands ²CLR WDT1² and ²CLR WDT2². For the first option, a simple execution of ²CLR WDT² will clear the WDT while for the second option, both ²CLR WDT1 ² and ²CLR WDT2² must both be executed to successfully clear the WDT. Note that for this second option, if ²CLR WDT1² is used to clear the WDT, succes- sive executions of this instruction will have no effect, only the execution of a ²CLR WDT2² instruction will clear the WDT. Similarly, after the ²CLR WDT2² instruc- tion has been executed, only a successive ²CLR WDT1² instruction can clear the Watchdog Timer. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |