| 数据搜索系统,热门电子元器件搜索 |
|
ST7713 数据表(PDF) 26 Page - Sitronix Technology Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
ST7713 数据表(HTML) 26 Page - Sitronix Technology Co., Ltd. |
|
26 / 159 page ![]() ST7713 Ver 1.6 2008-05 26 9. Function description 9.1 Interface type selection The selection of given interfaces are done by setting P68, IM2, IM1, and IM0 pins as shown in following table. Table 9.1.1 Selection of MCU interface P68 IM2 IM1 IM0 Interface Read back selection - 0 - - 3-line serial interface Via the read instruction 0 1 0 0 8080 MCU 8-bit parallel RDX strobe (8-bit read data and 8-bit read parameter) 0 1 0 1 8080 MCU 16-bit parallel RDX strobe (16-bit read data and 8-bit read parameter) 0 1 1 0 8080 MCU 9-bit parallel RDX strobe (9-bit read data and 8-bit read parameter) 0 1 1 1 8080 MCU 18-bit parallel RDX strobe (18-bit read data and 8-bit read parameter) - 0 - - 3-line serial interface Via the read instruction 1 1 0 0 6800 MCU 8-bit parallel E strobe (8-bit read data and 8-bit read parameter) 1 1 0 1 6800 MCU 16-bit parallel E strobe (16-bit read data and 8-bit read parameter) 1 1 1 0 6800 MCU 9-bit parallel E strobe (9-bit read data and 8-bit read parameter) 1 1 1 1 6800 MCU 18-bit parallel E strobe (18-bit read data and 8-bit read parameter) Table 9.1.2 Pin connection according to various MCU interface P68 IM2 IM1 IM0 Interface RDX WRX D/CX Read back selection - 0 - - 3-line serial interface Note1 Note1 SCL D[17:1]: unused, D0: SDA 0 1 0 0 8080 8-bit parallel RDX WRX D/CX D[17:8]: unused, D7-D0: 8-bit data 0 1 0 1 8080 16-bit parallel RDX WRX D/CX D[17:16]: unused, D15-D0: 16-bit data 0 1 1 0 8080 9-bit parallel RDX WRX D/CX D[17:9]: unused, D8-D0: 9-bit data 0 1 1 1 8080 18-bit parallel RDX WRX D/CX D17-D0: 18-bit data - 0 - - 3-line serial interface Note1 D/CX SCL D[17:1]: unused, D0: SDA 1 1 0 0 6800 8-bit parallel E WRX RS D[17:8]: unused, D7-D0: 8-bit data 1 1 0 1 6800 16-bit parallel E WRX RS D[17:16]: unused, D15-D0: 16-bit data 1 1 1 0 6800 9-bit parallel E WRX RS D[17:9]: unused, D8-D0: 9-bit data 1 1 1 1 6800 18-bit parallel E WRX RS D17-D0: 18-bit data Note 1. Unused pins can be open, or connected to DGND or VDDI. 9.2 8080-series MCU parallel interface (P68=’0’) The MCU can use one of following interfaces: 11-lines with 8-data parallel interface, 12-lines with 9-data parallel interface, 19-line with 16-data parallel interface or 21-lines with 18-data parallel interface. The chip-select CSX (active low) enables/disables the parallel interface. RESX (active low) is an external reset signal. WRX is the parallel data write enable, RDX is the parallel data read enable and D[17:0] is parallel data bus. The LCD driver reads the data at the rising edge of WRX signal. The D/CX is the data/command flag. When D/CX=’1’, D[17:0] bits is either display data or command parameter. When D/C=’0’, D[17:0] bits is command. The 6800-series bi-directional interface can be used for communication between the micro controller and LCD driver. The selection of this interface is done when P68 pin is in low state (DGND). Interface bus width can be selected with IM2, IM1 and IM0. The interface functions of 8080-series parallel interface are given in following table. Table 9.2.1 The function of 8080-series parallel interface P68 IM2 IM1 IM0 Interface D/CX RDX WRX Read back selection 0 1 ↑ Write 8-bit command (D7 to D0) 1 1 ↑ Write 8-bit display data or 8-bit parameter (D7 to D0) 1 ↑ 1 Read 8-bit display data (D7 to D0) 0 1 0 0 8-bit parallel 1 ↑ 1 Read 8-bit parameter or status (D7 to D0) 0 1 ↑ Write 8-bit command (D7 to D0) 1 1 ↑ Write 16-bit display data or 8-bit parameter (D15 to D0) 1 ↑ 1 Read 16-bit display data (D15 to D0) 0 1 0 1 16-bit parallel 1 ↑ 1 Read 8-bit parameter or status (D7 to D0) 0 1 ↑ Write 8-bit command (D7 to D0) 1 1 ↑ Write 9-bit display data or 8-bit parameter (D8 to D0) 1 ↑ 1 Read 9-bit display data (D8 to D0) 0 1 1 0 9-bit parallel 1 ↑ 1 Read 8-bit parameter or status (D7 to D0) 0 1 ↑ Write 8-bit command (D7 to D0) 1 1 ↑ Write 18-bit display data or 8-bit parameter (D17 to D0) 1 ↑ 1 Read 18-bit display data (D17 to D0) 0 1 1 1 18-bit parallel 1 ↑ 1 Read 8-bit parameter or status (D7 to D0) Note: applied for command code: DAh, DBh, DCh, 04h, 09h, 0Ah, 0Bh, 0Ch, 0Dh, 0Eh, 0Fh |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |