| 数据搜索系统,热门电子元器件搜索 |
|
ST10F276Z5 数据表(PDF) 169 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST10F276Z5 数据表(HTML) 169 Page - STMicroelectronics |
|
169 / 239 page ![]() ST10F276Z5 Register set 169/239 22.10 System configuration registers The ST10F276Z5 registers are used for a different configuration of the overall system. These registers are described below. Note: SYSCON Reset Value is: 0000 0xx0 0x00 0000b . SYSCON (FF12h / 89h) SFR Reset value: 0xx0h 15 14 13 12 11 10 987 6543210 STKSZ ROM S1 SGT DIS ROM EN BYT DIS CLK EN WR CFG CS CFG PWD CFG OWD DIS BDR STEN XPEN VISI BLE XPER- SHARE RW RW RW RW RW RW RW RW RW RW RW RW RW RW Table 79. SYSCON description Bit Function XPER-SHARE XBUS peripheral share mode control ‘0’: External accesses to XBUS peripherals are disabled. ‘1’: XRAM1 and XRAM2 are accessible via the external bus during hold mode. External accesses to the other XBUS peripherals are not guaranteed in terms of AC timings. VISIBLE Visible mode control ‘0’: Accesses to XBUS peripherals are done internally. ‘1’: XBUS peripheral accesses are made visible on the external pins. XPEN XBUS peripheral enable bit ‘0’: Accesses to the on-chip X-peripherals and XRAM are disabled. ‘1’: The on-chip X-peripherals are enabled. BDRSTEN Bidirectional reset enable ‘0’: RSTIN pin is an input pin only. SW Reset or WDT Reset have no effect on this pin. ‘1’: RSTIN pin is a bidirectional pin. This pin is pulled low during internal reset sequence. OWDDIS Oscillator watchdog disable control ‘0’: Oscillator Watchdog (OWD) is enabled. If PLL is bypassed, the OWD monitors XTAL1 activity. If there is no activity on XTAL1 for at least 1 µs, the CPU clock is switched automatically to PLL’s base frequency (from 750 kHz to 3 MHz). ‘1’: OWD is disabled. If the PLL is bypassed, the CPU clock is always driven by XTAL1 signal. The PLL is turned off to reduce power supply current. PWDCFG Power-down mode configuration control ‘0’: Power-down mode can only be entered during PWRDN instruction execution if NMI pin is low, otherwise the instruction has no effect. To exit Power-down mode, an external reset must occur by asserting the RSTIN pin. ‘1’: Power-down mode can only be entered during PWRDN instruction execution if all enabled fast external interrupt EXxIN pins are in their inactive level. Exiting this mode can be done by asserting one enabled EXxIN pin or with external reset. CSCFG Chip select configuration control ‘0’: Latched Chip Select lines, CSx changes 1 TCL after rising edge of ALE. ‘1’: Unlatched Chip Select lines, CSx changes with rising edge of ALE. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |