| 数据搜索系统,热门电子元器件搜索 |
|
MMA6901K 数据表(PDF) 19 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MMA6901K 数据表(HTML) 19 Page - Freescale Semiconductor, Inc |
|
19 / 36 page ![]() Sensors Freescale Semiconductor 19 MMA690xQ 3.1.2 Exception Priority Table 3-1 provides a summary of exception conditions and order of priority. If an offset fault condition is detected simultaneously in both the X- and Y-axes, only the X-axis exception is reported by the device. Hold condition and self-test exceptions have equal priority; if both exceptions exist simultaneously, both are reported by the device. 3.2 COMMUNICATIONS PROTOCOL The Communications Protocol provides 11-bit acceleration data along with enhanced status notification in the event that an exception condition is detected. All transfers are 16-bits in length, with the intended operation indicated by a two-bit transfer type code transmitted by the SPI master. Device response depends upon the transfer type code and the internal state of the device. If no exception condition has been detected, the device returns register or acceleration data as requested. If an exception condition exists, response depends upon the requested operation and the exception. Exceptions are divided into four classes: behavioral, reset, transient, and critical. Cer- tain operations, such as register data write and register pointer write, will not be completed if an exception condition is detected during the associated SPI transfer. All exception conditions detected by MMA690xQ are listed in Table 3-1. Response to excep- tions is described below, and summarized in Table 3-3. If both T1 and T0 are set to a logic ‘1’ state, an invalid axis selection exception will be reported by the device. 3.2.1 Device Response Device response depends upon exception conditions which may be present at the time the transfer takes place. In case of multiple exceptions, the exception class of highest priority will determine response. Table 3-1. Exception Conditions Condition Status Bit Class SPI Clock Fault, Previous Transfer — Transient DIN Parity Fault, Previous Transfer — Transient Internal Data Error IDE Critical Error Internal Oscillator Fault — Critical Error Device Initialization DEVINIT Reset Device Reset DEVRES Reset Temperature Fault TF Critical Error Invalid Axis Selection — Transient Hold Condition — Behavioral Self-test — Behavioral Table 3-2. Transfer Type Codes T1 T0 Transfer Type 0 0 Register Operation 0 1 X-axis acceleration data 1 0 Y-axis acceleration data 1 1 Unused |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |