| 数据搜索系统,热门电子元器件搜索 |
|
TNETE110PM 数据表(PDF) 18 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETE110PM 数据表(HTML) 18 Page - Texas Instruments |
|
18 / 26 page ![]() ThunderLAN ™ TNETE110PM PCI ETHERNET ™ CONTROLLER SINGLE-CHIP 10 BASE-T SPWS029 – SEPTEMBER 1996 18 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 switching characteristics for 5-V and 3.3-V PCI (see Note 15 and Figure 4) PARAMETER MIN MAX UNIT tVAL Delay time, PCLK to bused signals valid (see Notes 16 and 17) 2 11 ns tVAL(PTP) Delay time, PCLK to bused signals valid point-to-point (see Notes 16 and 17) 2 12 ns ton Float to active delay 2 ns toff Active to float delay 28 ns NOTES: 15. Some of the timing symbols in this table are not currently listed with EIA or JEDEC standards for semiconductor symbology but are consistent with the PCI Local-Bus Specification, Revision 2.0. 16. Minimum times are measured with a 0-pF equivalent load; maximum times are measured with a 50-pF equivalent load. Actual test capacitance may vary, but results should be correlated to these specifications. 17. PREQ and PGNT are point-to-point signals, and have different output-valid delay and input-setup times than do bused signals. PGNT has a setup time of 10 ns; PREQ has a setup time of 12 ns. All other signals are bused. timing requirements for 5-V and 3.3-V PCI (see Note 16 and Figure 4) PARAMETER MIN MAX UNIT tsu Setup time, bused signals valid to PCLK (see Note 17) 7 ns tsu(PTP) Setup time to PCLK—point-to-point (see Note 17) 10, 12 ns th Input hold time from PCLK 0 ns tc Cycle time, PCLK (see Note 18) 30 500 ns tw(H) Pulse duration, PCLK high 11 ns tw(L) Pulse duration, PCLK low 11 ns tslew Slew rate, PCLK (see Note 19) 1 4 V/ns NOTES: 16. Some of the timing symbols in this table are not currently listed with EIA or JEDEC standards for semiconductor symbology but are consistent with the PCI Local-Bus Specification, Revision 2.0. 17. PREQ and PGNT are point-to-point signals, and have different output-valid delay and input-setup times than do bused signals. PGNT has a setup time of 10 ns; PREQ has a setup time of 12 ns. All other signals are bused. 18. As a requirement for frame transmission /reception, the minimum PCLK frequency varies with network speed. The clock may be stopped only in a low state. 19. Rise and fall times are specified in terms of the edge rate measured in V/ns. This slew rate must be met across the minimum peak-to-peak portion of the clock waveform. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |