AD7450ARM 数据表(PDF) 18 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7450ARM 数据表(HTML) 18 Page - Analog Devices |
|
18 / 24 page ![]() REV. PrJ PRELIMINARY TECHNICAL DATA –18– AD7450 Figure 20. Serial Interface Timing example 1 23 4 5 13 16 15 14 t 2 t 6 t 5 t 8 tQUIET CONVERT t B CS t ACQUISITION 12.5(1/fSCLK) 1/Throughput 10ns SCLK C This 664ns satisfies the requirement of 275ns for tACQ. From Figure 20, tACQ comprises of: 2.5(1/FSCLK) + t8 + tQUIET where t8 = 45ns. This allows a value of 119ns for tQUIET satisfying the minimum requirement of 100ns. As in this example and with other slower clock values, the signal may already be acquired before the conversion is complete but it is still necessary to leave 100ns minimum tQUIET between conversions. In example 2 the signal should be fully acquired at approximately point C in Figure 20. MODES OF OPERATION The mode of operation of the AD7450 is selected by controlling the logic state of the CS signal during a conversion. There are two possible modes of operation, Normal Mode and Power-Down Mode. The point at which CS is pulled high after the conversion has been initiated will determine whether or not the AD7450 will enter the power- down mode. Similarly, if already in power-down, CS controls whether the device will return to normal operation or remain in power-down. These modes of operation are designed to provide flexible power management options. These options can be chosen to optimize the power dissipa- tion/throughput rate ratio for differing application requirements. Normal Mode This mode is intended for fastest throughput rate perfor- mance. The user does not have to worry about any power-up times as the AD7450 is kept fully powered up. Figure 21 shows the general diagram of the operation of the AD7450 in this mode. The conversion is initiated on the falling edge of CS as described in the ‘Serial Interface Section’. To ensure the part remains fully powered up, CS must remain low until at least 10 SCLK falling edges have elapsed after the falling edge of CS. If CS is brought high any time after the 10th SCLK fall- ing edge, but before the 16th SCLK falling edge, the part will remain powered up but the conversion will be termi- nated and SDATA will go back into three-state. Sixteen serial clock cycles are required to complete the conversion and access the complete conversion result. CS may idle high until the next conversion or may idle low until sometime prior to the next conversion. Once a data transfer is complete, i.e. when SDATA has returned to three-state, another conversion can be initiated after the quiet time, tQUIET has elapsed by again bringing CS low. 4 LEADING ZEROS + CONVERSION RESULT SDATA 10 16 CS SCLK 1 Figure 21. Normal Mode Operation Power Down Mode This mode is intended for use in applications where slower throughput rates are required; either the ADC is powered down between each conversion, or a series of conversions may be performed at a high throughput rate and the ADC is then powered down for a relatively long duration between these bursts of several conversions. When the AD7450 is in the power down mode, all analog circuitry is powered down. To enter power down mode, the conversion process must be interrupted by bringing CS high anywhere after the second falling edge of SCLK and before the tenth falling edge of SCLK as shown in Figure 22. Once CS has been brought high in this window of SCLKs, the part will enter power down and the conver- sion that was initiated by the falling edge of CS will be terminated and SDATA will go back into three-state. The time from the rising edge of CS to SDATA three- state enabled will never be greater than t8 (see the ‘Timing Specifications’). If CS is brought high before the second SCLK falling edge, the part will remain in normal mode and will not power-down. This will avoid accidental power-down due to glitches on the CS line. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |