| 数据搜索系统,热门电子元器件搜索 |
|
AD7450ARM 数据表(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7450ARM 数据表(HTML) 19 Page - Analog Devices |
|
19 / 24 page ![]() REV. PrJ PRELIMINARY TECHNICAL DATA –19– AD7450 Figure 23. Exiting Power Down Mode SDATA CS INVALID DATA SCLK 116 VALID DATA 1 A THE PART BEGINS TO POWER UP THE PART IS FULLY POWERED UP WITH VIN FULLY ACQUIRED 10 10 16 tPOWERUP In order to exit this mode of operation and power the AD7450 up again, a dummy conversion is performed. On the falling edge of CS the device will begin to power up, and will continue to power up as long as CS is held low until after the falling edge of the 10th SCLK. The device will be fully powered up after 1µsec has elapsed and, as shown in Figure 23, valid data will result from the next conversion. If CS is brought high before the 10th falling edge of SCLK, the AD7450 will again go back into power-down. This avoids accidental power-up due to glitches on the CS line or an inadvertent burst of eight SCLK cycles while CS is low. So although the device may begin to power up on the falling edge of CS, it will again power-down on the rising edge of CS as long as it occurs before the 10th SCLK falling edge. CS THREE STATE SCLK SDATA 12 10 Figure 22. Entering Power Down Mode Power up Time The power up time of the AD7450 is typically 1µsec, which means that with any frequency of SCLK up to 18MHz, one dummy cycle will always be sufficient to allow the device to power-up. Once the dummy cycle is complete, the ADC will be fully powered up and the input signal will be acquired properly. The quiet time tQUIET must still be allowed from the point at which the bus goes back into three-state after the dummy conversion, to the next falling edge of CS. When running at the maximum throughput rate of 1MSPS, the AD7450 will power up and acquire a signal within ±0.5LSB in one dummy cycle, i.e. 1µs. When powering up from the power-down mode with a dummy cycle, as in Figure 23, the track and hold, which was in hold mode while the part was powered down, returns to track mode after the first SCLK edge the part receives after the falling edge of CS. This is shown as point A in Figure 23. Although at any SCLK frequency one dummy cycle is sufficient to power the device up and acquire VIN, it does not necessarily mean that a full dummy cycle of 16 SCLKs must always elapse to power up the device and acquire VIN fully; 1µs will be sufficient to power the de- vice up and acquire the input signal. For example, if a 5MHz SCLK frequency was applied to the ADC, the cycle time would be 3.2µs (i.e. 1/(5MHz) x 16). In one dummy cycle, 3.2µs, the part would be powered up and VIN acquired fully. However after 1µs with a 5MHz SCLK only 5 SCLK cycles would have elapsed. At this stage, the ADC would be fully powered up and the signal acquired. So, in this case the CS can be brought high after the 10th SCLK falling edge and brought low again after a time tQUIET to initiate the con- version. When power supplies are first applied to the AD7450, the ADC may either power up in the power-down mode or normal mode. Because of this, it is best to allow a dummy cycle to elapse to ensure the part is fully powered up before attempting a valid conversion. Likewise, if the user wishes the part to power up in power-down mode, then the dummy cycle may be used to ensure the device is in power-down by executing a cycle such as that shown in Figure 22. Once supplies are applied to the AD7450, the power up time is the same as that when powering up from the power-down mode. It takes approximately 1µs to power up fully if the part powers up in normal mode. It is not necessary to wait 1µs before executing a dummy cycle to ensure the desired mode of operation. Instead, the dummy cycle can occur directly after power is supplied to the ADC. If the first valid conversion is then performed directly after the dummy conversion, care must be taken to ensure that adequate acquisition time has been al- lowed. As mentioned earlier, when powering up from the power- down mode, the part will return to track upon the first SCLK edge applied after the falling edge of CS. How- ever, when the ADC powers up initially after supplies are applied, the track and hold will already be in track. This means if (assuming one has the facility to monitor the ADC supply current) the ADC powers up in the desired mode of operation and thus a dummy cycle is not re- |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |