| 数据搜索系统,热门电子元器件搜索 |
|
AN3308 数据表(PDF) 36 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3308 数据表(HTML) 36 Page - STMicroelectronics |
|
36 / 52 page ![]() Click and double click recognition AN3308 36/52 Doc ID 18198 Rev 1 8.4.1 Playing with TAP_TimeLimit Figure 17 shows an acquisition carried out with TAP_TimeLimit = 01h (2.5 ms). With this setting, the single click recognition window is short and often the acceleration does not return below the threshold in time. In Figure 18 an acquisition done with TAP_TimeLimit = 33h (127 ms) is shown. With this setting the single click recognition window is longer, and it is easier for the event to be recognized. Figure 17. Short TimeLimit Figure 18. Long TimeLimit |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|