| 数据搜索系统,热门电子元器件搜索 |
|
AS0260CSSC28SUD20 数据表(PDF) 60 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
AS0260CSSC28SUD20 数据表(HTML) 60 Page - ON Semiconductor |
|
60 / 83 page ![]() AS0260 DS Rev. G Pub. 5/15 EN 60 ©Semiconductor Components Industries, LLC, 2015. AS0260: 1/6-Inch 1080P High-Definition (HD) System-On-A-Chip (SOC) Digi- tal Image Sensor UVC Configuration and Status The following subsections detail the UVC configuration and status variables. These do not form part of the UVC standard. They are provided to allow the implementation (or meaning) of selected UVC controls to be configured. Manual Exposure Configuration The UVC_FRAME_INTERVAL_CONTROL variable (frame-interval) allows the host to set the frame-rate, and the UVC_EXPOSURE_TIME_ABSOLUTE_CONTROL (exposure time) variable allows the host to directly control the exposure time (both provided auto-expo- sure mode is disabled). However, in some cases it may be appropriate for the exposure time to be limited: • Such that exposure cannot exceed the current frame interval • Such that image flicker is avoided by constraining exposure to multiples of the power- line frequency period If DISABLE_FIXED_FRAME_RATE (bit 0) is clear, any change in exposure time will be rejected if it exceeds the current value of frame-interval. If DISABLE_FIXED_- FRAME_RATE is set, the AS0260 will accept any value of exposure time (subject to its permitted range, and the state of bit 1). Note also that if DISABLE_FIXED_FRAME_RATE is clear, if frame-interval is reduced to a value below the current exposure time value, the AS0260 will automatically reduce the exposure time. If ENABLE_FLICKER_AVOIDANCE (bit 1) is set, any change in exposure time will be rounded-down to the nearest next multiple of the power-line frequency period. No error will be reported. If ENABLE_FLICKER_AVOIDANCE is clear, the AS0260 will accept any value of exposure time (subject to its permitted range). Note: The default configuration is to restrict exposure time such that it will not exceed the frame-interval - this conforms to the UVC 1.1 specification. Flicker Avoidance Configuration Configures the AS0260 flicker-avoidance algorithm. The flicker-avoidance algorithm can operate in two modes: • Flicker-avoidance: exposure time is restricted to multiples of the flicker period, regardless of the scene brightness. • Flicker-avoidance with outdoor override: exposure time is restricted to multiples of the flicker period, unless the scene brightness is typical for an 'outdoor' scene (where power line frequency flicker artefacts are not expected). In these brighter scenes, AE can choose the most appropriate exposure time. Variable Name Type Default R0xCC20 VAR(0x13,0x0020) UVC_MANUAL_EXPOSURE_CONFIG BITFIELD8 0x0 (fixed frame rate, no flicker avoidance) Variable Name Type Default 0xCC21 VAR(0x13,0x0021) UVC_FLICKER_AVOIDANCE_CONFIG BITFIELD8 Dependent upon CAM configuration |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |