57 / 70 page ![]() DocID029344 Rev 2 57/70 STGAP1AS Programming manual 70 The 2LTOtime parameter sets the duration of the 2-level turn-off sequence (refer to Section 7.10 on page 33 for details). If the 2LTOtime is set to zero, the 2-level turn-off feature is disabled. Table 36. 2LTOth 2LTOth [3 ... 0] 2LTO threshold value [V] 00 00 7.00 00 01 7.50 00 10 8.00 00 11 8.50 01 00 9.00 01 01 9.50 0 1 1 0 10.00 0 1 1 1 10.50 10 00 11.00 10 01 11.50 1 0 1 0 12.00 1 0 1 1 12.50 1 1 0 0 13.00 1 1 0 1 13.50 1 1 1 0 14.00 1 1 1 1 14.50 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|