| 数据搜索系统,热门电子元器件搜索 |
|
IC-HT 数据表(PDF) 14 Page - IC-Haus GmbH |
|
|
|||||||||||||||||||||||||||||
IC-HT 数据表(HTML) 14 Page - IC-Haus GmbH |
|
14 / 45 page ![]() prel imin ary prel imin ary iC-HT DUAL CW LASER DIODE DRIVER Rev B1, Page 14/45 MICROCONTROLLER MODE Setting pin EMC to hi configures iC-HT for microcon- troller mode (MCU mode). EMC pin must be set us- ing a pull-up resistor or directly short-circuited to VDD pin. Several parameters can be configured through a microcontroller via I2C or SPI communication. More in- formation about the serial communication interface can be found on page 23. The configuration of the internal parameters of iC-HT must be done in configuration mode. In this mode, the configuration memory can be written and read back without changing the previous configuration state of iC-HT. Once the configuration is considered as valid, iC-HT can be switched to operation mode. These two modes are configured by the MODE register. If the time in configuration mode exceeds the Configuration Mode Timeout (cf. Electrical Characteristics No. E02), both channels will be switched off. More information on page 34. Each individual channel can be enabled by setting pin ECx to hi. Setting register bits DISCx to 1 disables the corresponding channel. If either pin ECx is lo or register bits DISCx is 1, the corresponding channel is disabled. DISC1 Addr. 0x10; bit 3 R/W 1 0 Channel 1 can be enabled by pin EC1 1 Channel 1 cannot be enabled by pin EC1 Table 6: Disable channel 1 DISC2 Addr. 0x15; bit 3 R/W 1 0 Channel 2 can be enabled by pin EC2 1 Channel 2 cannot be enabled by pin EC2 Table 7: Disable channel 2 Different voltages can be measured using a 10 bit A/D converter with two resolutions. The following internal voltages can be measured: • V(LDKx) up to 8 V with 8.6 mV resolution • V(VDD) up to 8 V with 8.6 mV resolution • V(VB) up to 8 V with 8.6 mV resolution • V(MDAx) up to 1 V with 1.075 mV resolution • V(PLRx) up to 1 V with 1.075 mV resolution The register bits ADCCx select the signal measured with the 10 bit A/D converter. ADCC1(2:0) Addr. 0x10; bit 7:5 R/W 000 0xx Disabled 100 V(MDA1), ADSNF1 = 0 100 V(PLR1), ADSNF1 = 1 101 V(VB) 110 V(VDD) 111 V(LDK1) Table 8: ADC channel 1 source selection ADCC2(2:0) Addr. 0x15; bit 7:5 R/W 000 0xx Disabled 100 V(MDA2), ADSNF2 = 0 100 V(PLR2), ADSNF2 = 1 101 V(VB) 110 V(VDD) 111 V(LDK2) Table 9: ADC channel 2 source selection With ADCCx(2:0) = 100, the signal to the A/D converter is selected by register bit ADSNFx. With ADSNFx = 1 the measuring point to the A/D converter is the internal sense node of the internal programmable logarithmic monitor resistor (PLR). With ADSNFx = 0 the sensing point is connected directly to MDAx pin. ADSNF1 Addr. 0x1A; bit 2 R/W 0 0 ADC measurement pin MDA1 (force) 1 ADC measurement PLR1 (sense) Table 10: ADC channel 1 sense/force selection ADSNF2 Addr. 0x1A; bit 6 R/W 0 0 ADC measurement pin MDA2 (force) 1 ADC measurement PLR2 (sense) Table 11: ADC channel 2 sense/force selection |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |