| 数据搜索系统,热门电子元器件搜索 |
|
IC-HT 数据表(PDF) 33 Page - IC-Haus GmbH |
|
|
|||||||||||||||||||||||||||||
IC-HT 数据表(HTML) 33 Page - IC-Haus GmbH |
|
33 / 45 page ![]() prel imin ary prel imin ary iC-HT DUAL CW LASER DIODE DRIVER Rev B1, Page 33/45 TEMPERATURE MONITOR AND PROTECTION iC-HT includes an 8 bit temperature monitor that al- lows to measure the internal chip temperature going from -40 °C to 125 °C. The resolution is 1 °C/LSB. The internal temperature can be obtained by reading TEMP register. The TEMP register is a read-only register. TEMP Addr. 0x02; bit 7:0 R 0x00 Minimum temperature . . . 0xFF Maximum temperature Table 64: Chip temperature Absolute read values may differ from one chip to an- other. An individual initial calibration of the temper- ature monitor is recommended. The TEMP register must be read at a known temperature. Using the reso- lution value of 1 °C/LSB, the internal temperature can be calculated. The temperature monitor can be used to compensate temperature effects on the laser diode. The microcon- troller can use a laser diode characteristic formula or a look-up table combined with the temperature value measured through TEMP register. The reference volt- age can be configured accordingly in order to compen- sate temperature effects. iC-HT is protected against overtemperature. In iC- WK mode, if the internal temperature value exceeds the overtemperature threshold an OVT error event will be triggered and signaled through pin NCHK. Both laser channels will be disabled. Pin NCHK will keep signaling the error although the internal temperature goes down to a safe value below the overtemperature threshold value. If the temperature has exceeded the overtemperature threshold value, pins EC1 and EC2 have to be pulled lo in order to stop signaling the error. Setting pin ECx back hi will re-enable the correspond- ing channel. In microcontroller mode, if the internal temperature exceeds a safety value an overtemperature error bit (OVT) will be set to 1. If OVT = 1, both channels will be disabled and the error event will be signaled through NCHK pin. If the internal temperature goes down to a safe value below the overtemperature threshold value, OVT will remain at value 1. Reading the OVT bit stop signaling error through pin NCHK. Reading OVT bit will set it back to 0. Setting ECx pin lo and then back hi will allow re-enabling the corresponding channel. The overtemperature threshold value can not be con- figured. OVT Addr. 0x00; bit 3 R 0 No overtemperature event has occurred since last read 1 Overtemperature event has occurred. Cleared on read Table 65: Overtemperature detection In microcontroller mode it is possible to simulate an overtemperature event using SOVT bit. Setting SOVT to 1, the overtemperature error flag OVT will be set to 1. iC-HT will remain in error state until SOVT is set back to 0. SOVT Addr. 0x1D; bit 4 R/W 0 0 No overtemperature event is simulated. 1 Overtemperature event simulated. Table 66: Simulate overtemperature |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |