25 / 32 page ![]() REV. 0 ADE7756 –25– Assuming the meter is set up with a test current (basic current) of 20 A and a line voltage of 220 V for calibration, the load is calculated as 220 V × 20 A = 4.4 kW. Therefore the expected output frequency on CF under this steady load condition would be 4.4 × 0.8888 Hz = 3.9111 Hz. Under these load conditions the transducers on Channel 1 and Channel 2 should be selected such that the signal on the voltage channel should see approximately half scale and the signal on the current channel about 1/8 of full scale (assuming a maximum current of 80A). The average value from LPF2 is calculated as 3,276.81 decimal using the calibration mode as described above. Then, using Equation 8 (Energy to Frequency Conver- sion), the frequency under this load is calculated as: Frequency CF MHz Hz () .. . = × = 3276 81 3 579545 2 349 566 25 However, this is the frequency with the contents of the CFDIV and APGAIN registers equal to 000h. The desired frequency out is 3.9111 Hz. Therefore the CF frequency must be divided by 349.566/3.9111 Hz or 89.378 decimal. This is achieved by loading the CF Divide register with 88 (or 58h)—Note the CF frequency is divided by the contents of CFDIV + 1. The fine adjustment of the output frequency can be made using the Active Power Gain register. This register has a fine gain adjustment of 0.0244%/LSB. With the CF Divide register con- tents equal to 58h, the output frequency is given as 349.556 Hz/ 89 = 3.9276 Hz. This setting has an error of 0.42%. This error can be further reduced by writing –(0.21/0.0244) or –17 to APGAIN[11:0] i.e., FEFh. Calibrating CF is made easy by using the Calibration mode on the ADE7756. The only critical part of the setup is that the line frequency be exactly known. If this is not possible, it could be measured by using the ZX output of the ADE7756. Energy Meter Display Besides the pulse output which is used to verify calibration, a solid state energy meter will very often require some form of display. The display should display the amount of energy con- sumed in kWh (Kilowatt Hours). One convenient and simple way to interface the ADE7756 to a display or energy register (e.g., MCU with nonvolatile memory) is to use CF. For example the CF frequency could be calibrated to 1,000 imp/kWh. The MCU would count pulses from CF. Every pulse would be equivalent to 1 watt-hour. If more resolution is required the CF frequency could be set to, say, 10,000 imp/kWh. If more flexibility is required when monitoring energy usage, the Active Energy register (AENERGY) can be used to calculate energy. A full description of this register can be found in the Energy Calculation section. The AENERGY register gives the user both sign and magnitude information regarding energy consumption. On completion of the CF frequency output cali- bration, i.e., after the Active Power Gain (APGAIN) register has been adjusted, a second calibration sequence can be initiated. The purpose of this second calibration routine is to determine a kWh/LSB coefficient for the AENERGY register. Once the coefficient has been calculated the MCU can determine the energy consumption at any time by reading the AENERGY contents and multiplying by the coefficient to calculate kWh. CLKIN FREQUENCY In this data sheet, the characteristics of the ADE7756 are shown with CLKIN frequency equal to 3.579545 MHz. However, the ADE7756 is designed to have the same accuracy at any CLKIN frequency within the specified range. If the CLKIN frequency is not 3.579545 MHz, various timing and filter characteristics will need to be redefined with the new CLKIN frequency. For example, the cut-off frequencies of all digital filters (LPF1, LPF2, HPF1, etc.) will shift in proportion to the change in CLKIN frequency according to the following equation: New Frequency Original Frequency CLKIN Frequency MHz =× 3 579545 . (17) The change of CLKIN frequency does not affect the timing characteristics of the serial interface because the data transfer is synchronized with serial clock signal (SCLK). But one needs to observe the read/write timing of the serial data transfer-see Timing Characteristics. Table III lists various timing changes that are affected by CLKIN frequency. APPLICATION INFORMATION Application note AN-564 contains detail information on how to design a ANSI Class 100 Watt-Hour meter based on the ADE7756. It is available from the ADE7756 product home page under the Application Note link. Figure 35 shows the block dia- gram of the ADE7756 reference meter implemented in AN-564. RS-232 220V LOAD L1 L2 N ADE7756 16 2 LCD DISPLAY EEPROM SPI BUS PIC16C62B CF Figure 35. Block Diagram of the ADE7756 Reference Meter Described in AN-564 Table III. Frequency Dependencies of the ADE7756 Parameters CLKIN Parameter Dependency Nyquist Frequency for CH 1 and 2 ADCs CLKIN/8 PHCAL Resolution (Seconds per LSB) 16/CLKIN Active Energy Register Update Rate (Hz) CLKIN/4 Waveform Sampling Rate (Number of Samples per Second) WAVSEL 1, 0 = 0 0 CLKIN/128 0 1 CLKIN/256 1 0 CLKIN/512 1 1 CLKIN/1024 Maximum ZXTOUT Period 524,288/CLKIN |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |